Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

CGRP Kit ELISA

CALCA Reactivité: Souris Colorimetric 15.6-1000 pg/mL Plasma, Serum, Tissue Homogenate
N° du produit ABIN1095216
  • Antigène Voir toutes CGRP (CALCA) Kits ELISA
    CGRP (CALCA) (Calcitonin-Related Polypeptide alpha (CALCA))
    Reactivité
    • 6
    • 6
    • 5
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Souris
    Méthode de détection
    Colorimetric
    Gamme de detection
    15.6-1000 pg/mL
    Seuil minimal de détection
    15.6 pg/mL
    Application
    ELISA
    Type d'échantillon
    Serum, Plasma, Tissue Homogenate
    Analytical Method
    Quantitative
    Réactivité croisée (Details)
    Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between the target antigen and all analogues for other species. Therefore, cross reaction may still exist.
    Sensibilité
    3.9 pg/mL
    Ingrédients
    • Assay plate (12 × 8 coated Microwells)
    • Standard (freeze dried)
    • Biotin-antibody (100 × concentrate)
    • HRP-avidin (100 × concentrate)
    • Biotin-antibody Diluent
    • HRP-avidin Diluent
    • Sample Diluent
    • Wash Buffer (25 × concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip (for 96 wells)
    • Instruction manual
    Matériel non inclus
    • Microplate reader capable of measuring absorbance at 450nm, with the correction wavelength set at 540nm or 570nm.
    • An incubator which can provide stable incubation conditions up to 37°C ± 0.5°C.
    • Squirt bottle, manifold dispenser or automated microplate washer.
    • Absorbent paper for blotting the microtiter plate.
    • 100mL and 500mL graduated cylinders.
    • Deionized or distilled water.
    • Pipettes and pipette tips.
    • Test tubes for dilution.
    Featured
    Discover our best selling CALCA Kit ELISA
    Top Product
    Discover our top product CALCA Kit ELISA
  • Indications d'application
    • The supplier is only responsible for the kit itself, but not for the samples consumed during the assay. The user should calculate the possible amount of the samples used in the whole test. Please reserve sufficient samples in advance.
    • Samples to be used within 5 days may be stored at 2-8°C, otherwise samples must be stored at -20°C (≤ 1 month) or -80°C (≤ 2 months) to avoid loss of bioactivity and contamination.
    • Grossly hemolyzed samples are not suitable for use in this assay.
    • If the samples are not indicated in the manual, a preliminary experiment to determine the validity of the kit is necessary.
    • Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their particular experiments.
    • Tissue or cell extraction samples prepared by chemical lysis buffer may cause unexpected ELISA results due to the impacts of certain chemicals.
    • Owing to the possibility of mismatching between antigens from another resource and antibodies used in this supplier's kits (e.g., antibody targets conformational epitope rather than linear epitope), some native or recombinant proteins from other manufacturers may not be recognized by this supplier's products.
    • Influenced by factors including cell viability, cell number and cell sampling time, samples from cell culture supernatant may not be recognized by the kit.
    • Fresh samples without long time storage are recommended for the test. Otherwise, protein degradation and denaturalization may occur in those samples and finally lead to wrong results.
    Commentaires

    Detection wavelength: 450 nm

    Information on standard material:
    Depending on the antigen to be detected, standards can be either native or recombinant protein. The recombinant proteins are being expressed in CHO cells in most cases. Please inquire for more information. The formulation of auxiliary material in the standard is considered proprietary information, however it does not contain any poisonous substance. Proclin 300 (1:3000) is used as preservative.

    Information on reagents:
    In most cases the stop solution provided is 1 N H2SO4. The formulation of wash solution is proprietary information. None of the components contain (sodium) azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials. For the sandwich method kits, the sample diluent, antibody diluent, enzyme diluent and standard all contain BSA.

    Information on antibodies:
    The antibodies provided in different kits vary in regards to clonality and host. Some antibodies are affinity purified, some are Protein A

    Durée du test
    1 - 4.5 h
    Plaque
    Pre-coated
    Prélèvement de l'échantillon
    • Serum: Use a serum separator tube (SST) and allow samples to clot for two hours at room temperature or overnight at 4 °C before centrifugation for 15 minutes at 1000 × g. Remove serum and assay immediately or aliquot and store samples at -20 °C or -80 °C. Avoid repeated freeze-thaw cycles.
    • Plasma: Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 × g at 2-8 °C within 30 minutes of collection. Assay immediately or aliquot and store samples at -20 °C or -80 °C. Avoid repeated freeze-thaw cycles.
    • Tissue Homogenates: Rinse 100 mg tissue with 1× PBS, homogenize in 1mL of 1× PBS and store overnight at -20 °C. After two freeze-thaw cycles to break the cell membranes, centrifuge the homogenates for 5 minutes at 5000 × g, 2-8 °C. Remove and assay the supernate immediately. Alternatively, aliquot and store samples at -20 °C or -80 °C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
    Calcul des résultats

    Average the duplicate readings for each standard and sample and subtract the average zero standard optical density.
    Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the target antigen concentration versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data.
    If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

    Précision du teste
    Intra-assay precision (precision within an assay): Three samples of known concentration were tested twenty times on one plate to assess precision.
    Inter-assay precision (precision between assays): Three samples of known concentration were tested in twenty assays to assess precision.
    • Intra-assay: CV% less than 8%
    • Inter-assay: CV% less than 10%
    Restrictions
    For Research Use only
  • Précaution d'utilisation
    The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face and clothing protection when using this material.
    Conseil sur la manipulation
    • The kit should not be used beyond the expiration date on the kit label.
    • Do not mix or substitute reagents with those from other lots or sources.
    • If samples generate values higher than the highest standard, dilute the samples with Sample Diluent and repeat the assay.
    • Any variation in Sample Diluent, operator, pipetting technique, washing technique, incubation time/temperature and kit age can cause variation in binding.
    • This assay is designed to eliminate interference by soluble receptors, binding proteins and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
    Stock
    4 °C/-20 °C
    Stockage commentaire
    For unopened kit: All the reagents should be kept according to the labels on vials.
    Date de péremption
    6 months
  • Lv, Zhu, Xu, Gao, Xiao: "Inhibition of carrageenan-induced dental inflammatory responses owing to decreased TRPV1 activity by Dexmedetomidine." dans: Journal of inflammation (London, England), Vol. 17, pp. 18, (2020) (PubMed).

    Mao, Shi, Wang, Luo, Wang, Li, Lu, Ju, Xu, Kong, Zhou, Shen, Li: "Chemical profiles and pharmacological activities of Chang-Kang-Fang, a multi-herb Chinese medicinal formula, for treating irritable bowel syndrome." dans: Journal of ethnopharmacology, Vol. 201, pp. 123-135, (2017) (PubMed).

  • Antigène Voir toutes CGRP (CALCA) Kits ELISA
    CGRP (CALCA) (Calcitonin-Related Polypeptide alpha (CALCA))
    Autre désignation
    calcitonin gene related peptide (CGRP) (CALCA Produits)
    Synonymes
    CALC1 Kit ELISA, CGRP Kit ELISA, CGRP-I Kit ELISA, CGRP1 Kit ELISA, CT Kit ELISA, KC Kit ELISA, CALC Kit ELISA, CALCA Kit ELISA, CALC3 Kit ELISA, ci-ct Kit ELISA, calca Kit ELISA, CA Kit ELISA, CGRP-1 Kit ELISA, Calc Kit ELISA, Calc1 Kit ELISA, Cgrp Kit ELISA, Ct Kit ELISA, Ctn Kit ELISA, calcitonin Kit ELISA, CAL6 Kit ELISA, Cal1 Kit ELISA, RATCAL6 Kit ELISA, CGRPI Kit ELISA, calc Kit ELISA, cgrp Kit ELISA, zgc:92886 Kit ELISA, calcitonin related polypeptide alpha Kit ELISA, calcitonin related polypeptide beta Kit ELISA, calcitonin-related polypeptide alpha Kit ELISA, calcitonin Kit ELISA, calcitonin/calcitonin-related polypeptide, alpha Kit ELISA, calcitonin-related polypeptide beta Kit ELISA, calcitonin gene-related peptide 2 Kit ELISA, CALCA Kit ELISA, CALCB Kit ELISA, ci-ct Kit ELISA, calca Kit ELISA, Calca Kit ELISA, LOC100008771 Kit ELISA
    Pathways
    Hormone Activity, cAMP Metabolic Process, Myometrial Relaxation and Contraction, Regulation of G-Protein Coupled Receptor Protein Signaling, Skeletal Muscle Fiber Development, Feeding Behaviour
Vous êtes ici:
Support technique