Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

SLC1A2 Kit ELISA

SLC1A2 Reactivité: Humain Colorimetric Sandwich ELISA 0.312 ng/mL - 20 ng/mL Cell Lysate, Tissue Homogenate
N° du produit ABIN1569502
  • Antigène Voir toutes SLC1A2 Kits ELISA
    SLC1A2 (Solute Carrier Family 1 (Glial High Affinity Glutamate Transporter), Member 2 (SLC1A2))
    Reactivité
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.312 ng/mL - 20 ng/mL
    Seuil minimal de détection
    0.312 ng/mL
    Application
    ELISA
    Fonction
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of EAAT2 in human tissue homogenates, cell lysates and other biological fluids.
    Type d'échantillon
    Cell Lysate, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of this index.
    Réactivité croisée (Details)
    No significant cross-reactivity or interference between this index and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross- reactivity detection between this index and all the analogues, therefore, cross reaction may still exist.
    Sensibilité
    0.113 ng/mL
    Ingrédients
    • Pre-coated, ready to use 96-well strip plate
    • Standard (freeze dried)
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • TMB
    • Stop Solution
    • Wash Buffer (30X)
    • Plate sealer for 96 wells
    • Instruction manual
    Matériel non inclus
    1. Microplate reader with 450 ± 10nm filter.
    2. Precision single or multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. Deionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling SLC1A2 Kit ELISA
    Top Product
    Discover our top product SLC1A2 Kit ELISA
  • Volume d'échantillon
    100 μL
    Durée du test
    1 - 4.5 h
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards
    2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
    3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
    4. Aspirate and wash 3 times
    5. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
    6. Aspirate and wash 5 times
    7. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
    8. Add 50µL Stop Solution. Read at 450nm immediately.
    Procédure de l'essai

    The microtiter plate provided in this kit has been pre-coated with an antibody specific to the index. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to the index. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain the index, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of the index in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Précision du teste
    • Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
    • Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
    • CV(%) = SD/meanX100
    • Intra-assay: CV<10%
    • Inter-assay: CV<12%
    Restrictions
    For Research Use only
  • Précaution d'utilisation
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    Conseil sur la manipulation
    The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
    Stock
    4 °C,-20 °C
    Stockage commentaire
    The Assay Plate, Standard, Detection Reagent A and Detection Reagent B should be stored at -20°C upon being received. After receiving the kit , Substrate should be always stored at 4°C.Other reagents are kept according to the labels on vials. But for long term storage, please keep the whole kit at -20°C. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit (six months from the date of manufacture). Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
    Date de péremption
    12 months
  • Antigène Voir toutes SLC1A2 Kits ELISA
    SLC1A2 (Solute Carrier Family 1 (Glial High Affinity Glutamate Transporter), Member 2 (SLC1A2))
    Autre désignation
    EAAT2 (SLC1A2 Produits)
    Synonymes
    CG3159 Kit ELISA, Dmel\\CG3159 Kit ELISA, EAAT Kit ELISA, dEAAT2 Kit ELISA, dEaat2 Kit ELISA, Eaat Kit ELISA, GB16377 Kit ELISA, EAAT2 Kit ELISA, SLC1A2 Kit ELISA, Eaat2 Kit ELISA, Glt Kit ELISA, Glt-1 Kit ELISA, GLT-1 Kit ELISA, 1700091C19Rik Kit ELISA, 2900019G14Rik Kit ELISA, AI159670 Kit ELISA, GLT1 Kit ELISA, MGLT1 Kit ELISA, eaat2 Kit ELISA, fj34b12 Kit ELISA, slc1a2 Kit ELISA, wu:fj34b12 Kit ELISA, zgc:65897 Kit ELISA, Excitatory amino acid transporter 2 Kit ELISA, excitatory amino acid transporter 2 Kit ELISA, solute carrier family 1 member 2 Kit ELISA, solute carrier family 1 (glial high affinity glutamate transporter), member 2 Kit ELISA, solute carrier family 1 (glial high affinity glutamate transporter), member 2b Kit ELISA, Eaat2 Kit ELISA, Eaat-2 Kit ELISA, SLC1A2 Kit ELISA, VDBG_06180 Kit ELISA, EUBELI_01747 Kit ELISA, Trebr_0139 Kit ELISA, Slc1a2 Kit ELISA, slc1a2b Kit ELISA
    Sujet
    Alternative name: SLC1A2, EAAT2, GLT-1, Solute Carrier Family 1 Member 2, Glutamate/aspartate transporter II, Sodium-dependent glutamate/aspartate transporter 2
    ID gène
    6506
    UniProt
    P43004
    Pathways
    Dicarboxylic Acid Transport
Vous êtes ici:
Support technique