Transferrin Kit ELISA

TF Reactivité: Souris Colorimetric Competition ELISA 12.35 ng/mL - 1000 ng/mL Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
N° du produit ABIN3159712
  • Antigène Voir toutes Transferrin (TF) Kits ELISA
    Transferrin (TF)
    Reactivité
    • 7
    • 5
    • 4
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Souris
    Méthode de détection
    Colorimetric
    Type de méthode
    Competition ELISA
    Gamme de detection
    12.35 ng/mL - 1000 ng/mL
    Seuil minimal de détection
    12.35 ng/mL
    Application
    ELISA
    Fonction
    The kit is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of TRF in mouse serum, plasma, tissue homogenates, cell culture supernates and other biological fluids.
    Type d'échantillon
    Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificité

    This assay has high sensitivity and excellent specificity for detection of Transferrin (TRF).
    No significant cross-reactivity or interference between Transferrin (TRF) and analogues was observed.

    Réactivité croisée (Details)
    No significant cross-reactivity or interference between Transferrin (TRF) and analogues was observed.
    Sensibilité
    5.44 ng/mL
    Ingrédients
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • Reagent Diluent
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30 x concentrate)
    • Instruction manual
    Featured
    Discover our best selling TF Kit ELISA
    Top Product
    Discover our top product TF Kit ELISA
  • Indications d'application
    • Limited by the current condition and scientific technology, we cannot completely conduct the comprehensive identification and analysis on the raw material provided by suppliers. So there might be some qualitative and technical risks to use the kit.
    • The final experimental results will be closely related to validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available.
    • Kits from different batches may be a little different in detection range, sensitivity and color developing time.
    • Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
    • Protect all reagents from strong light during storage and incubation. All the bottle caps of reagents should be covered tightly to prevent the evaporation and contamination of microorganism.
    • There may be some foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
    • Wrong operations during the reagents preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
    • Even the same operator might get different results in two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before assay for each batch is recommended.
    • Each kit has been strictly passed Q.C test. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipments. Intra-assay variance among kits from different batches might arise from above factors, too.
    • Kits from different manufacturers for the same item might produce different results, since we have not compared our products with other manufacturers.
    Commentaires

    Information on standard material:
    The standard might be recombinant protein or natural protein, that will depend on the specific kit. Moreover, the expression system is E.coli or yeast or mammal cell. There is 0.05% proclin 300 in the standard as preservative.

    Information on reagents:
    The stop solution used in the kit is sulfuric acid with concentration of 1 mol/L. And the wash solution is TBS. The standard diluent contains 0.02 % sodium azide, assay diluent A and assay diluent B contain 0.01% sodium azide. Some kits can contain is BSA in them.

    Information on antibodies:
    The provided antibodies and their host vary in different kits.

    Volume d'échantillon
    50 μL
    Durée du test
    2 h
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards,
    2. Add 50μL standard or sample to each well.
      Then add 50μL prepared Detection Reagent A immediately.
      Shake and mix. Incubate 1 hour at 37 °C,
    3. Aspirate and wash 3 times,
    4. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37 °C,
    5. Aspirate and wash 5 times,
    6. Add 90μL Substrate Solution. Incubate 10-20 minutes at 37 °C,
    7. Add 50μL Stop Solution. Read at 450 nm immediately.
    Préparation des réactifs
    • Bring all kit components and samples to room temperature (18-25 °C) before use.
    • Standard - Reconstitute the Standard with 1.0 mL of Standard Diluent, kept for 10 minutes at room temperature, shake gently (not to foam). The concentration of the standard in the stock solution is 500 ng/mL. Please prepare 5 tubes containing 0.6 mL Standard Diluent and produce a triple dilution series according to the picture shown below. Mix each tube thoroughly before the next transfer. Set up 5 points of diluted standard such as 500 ng/mL, 166.67 ng/mL, 55.56 ng/mL, 18.52 ng/mL, 6.17 ng/mL, and the last EP tubes with Standard Diluent is the blank as 0 ng/mL
    • Detection Reagent A and Detection Reagent B - Briefly spin or centrifuge the stock Detection A and Detection B before use. Dilute to the working concentration with Assay Diluent A and B, respectively (1:100).
    • Wash Solution - Dilute 20 mL of Wash Solution concentrate (30×) with 580 mL of deionized or distilled water to prepare 600 mL of Wash Solution (1×).
    • TMB substrate - Aspirate the needed dosage of the solution with sterilized tips and do not dump the residual solution into the vial again.
    Note:
    • Making serial dilution in the wells directly is not permitted.
    • Prepare standard within 15 minutes before assay. Please do not dissolve the reagents at 37 °C directly.
    • Detection Reagent A and B are sticky solutions, therefore, slowly pipette them to reduce the volume errors.
    • Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals are completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10myL for once pipetting.
    • The reconstituted Standards, Detection Reagent A and Detection Reagent B can be used only once.
    • If crystals have formed in the Wash Solution concentrate (30×), warm to room temperature and mix gently until the crystals are completely dissolved.
    • Contaminated water or container for reagent preparation will influence the detection result.
    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Transferrin (TRF) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Transferrin (TRF) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions
    For Research Use only
  • Précaution d'utilisation
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    Conseil sur la manipulation
    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
    Stock
    4 °C
    Stockage commentaire
    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.
    Date de péremption
    6 months
  • Liu, Liu, Liu, Miao, Guo, Song, Wang, Zhou, Ganz, Yan, Liu: "New thiazolidinones reduce iron overload in mouse models of hereditary hemochromatosis and β-thalassemia." dans: Haematologica, Vol. 104, Issue 9, pp. 1768-1781, (2020) (PubMed).

    Mizugishi, Inoue, Hatayama, Bielawski, Pierce, Sato, Takaori-Kondo, Konishi, Yamashita: "Sphingolipid Pathway Regulates Innate Immune Responses at the Fetomaternal Interface during Pregnancy." dans: The Journal of biological chemistry, Vol. 290, Issue 4, pp. 2053-68, (2015) (PubMed).

  • Antigène Voir toutes Transferrin (TF) Kits ELISA
    Transferrin (TF)
    Autre désignation
    Transferrin (TRF) (TF Produits)
    Synonymes
    ltf Kit ELISA, pro1557 Kit ELISA, pro2086 Kit ELISA, mgc107777 Kit ELISA, LOC692564 Kit ELISA, TF Kit ELISA, LOC100144362 Kit ELISA, tf Kit ELISA, LTF Kit ELISA, TFEW Kit ELISA, conalbumin Kit ELISA, tf-b Kit ELISA, MGC64306 Kit ELISA, PRO1557 Kit ELISA, PRO2086 Kit ELISA, TFQTL1 Kit ELISA, AI266983 Kit ELISA, Cd176 Kit ELISA, HP Kit ELISA, Tf Kit ELISA, Tfn Kit ELISA, hpx Kit ELISA, Trf Kit ELISA, cb285 Kit ELISA, gavi Kit ELISA, id:ibd3238 Kit ELISA, id:ibd3525 Kit ELISA, sb:cb285 Kit ELISA, wu:fb57g06 Kit ELISA, wu:fb62h02 Kit ELISA, wu:fb63h10 Kit ELISA, wu:fb64h10 Kit ELISA, zgc:112154 Kit ELISA, 143958_at Kit ELISA, CG6186 Kit ELISA, Dmel\\CG6186 Kit ELISA, TSF1 Kit ELISA, anon-EST:Posey265 Kit ELISA, tsf1 Kit ELISA, Pro-TRH Kit ELISA, IL-5 Kit ELISA, STF I Kit ELISA, TRF1 Kit ELISA, sTF1 Kit ELISA, sTf Kit ELISA, tf1 Kit ELISA, transferrin Kit ELISA, serotransferrin Kit ELISA, transferrin (ovotransferrin) Kit ELISA, transferrin L homeolog Kit ELISA, melanotransferrin Kit ELISA, transferrin-a Kit ELISA, Transferrin 1 Kit ELISA, thyrotropin releasing hormone Kit ELISA, interleukin 5 Kit ELISA, TF Kit ELISA, LOC477072 Kit ELISA, tf Kit ELISA, Tf Kit ELISA, LOC100144362 Kit ELISA, tf.L Kit ELISA, LOC5575625 Kit ELISA, Trf Kit ELISA, tfa Kit ELISA, Tsf1 Kit ELISA, TRH Kit ELISA, IL5 Kit ELISA, LOC101085148 Kit ELISA, LOC100726872 Kit ELISA, trf Kit ELISA
    UniProt
    Q921I1
    Pathways
    Transition Metal Ion Homeostasis
Vous êtes ici:
Support technique