AGT Kit ELISA

AGT Reactivité: Souris Colorimetric Competition ELISA 15.625-1000 pg/mL Plasma, Serum
N° du produit ABIN4993249
  • Antigène Voir toutes AGT Kits ELISA
    AGT (Angiotensinogen (serpin Peptidase Inhibitor, Clade A, Member 8) (AGT))
    Reactivité
    • 8
    • 7
    • 7
    • 5
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    Souris
    Méthode de détection
    Colorimetric
    Type de méthode
    Competition ELISA
    Gamme de detection
    15.625-1000 pg/mL
    Seuil minimal de détection
    15.625 pg/mL
    Application
    ELISA
    Fonction
    The kit is a competitive enzyme immunoassay for in vitro quantitative measurement of Ang-I in Mouse serum, plasma and other biological fluids
    Type d'échantillon
    Plasma, Serum
    Analytical Method
    Quantitative
    Specificité
    This kit recognizes natural and recombinant Mouse Ang-I. No significant cross-reactivity or interference between Mouse Ang-I and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between Mouse Ang-I and all the analogues.
    Sensibilité
    9.375 pg/mL
    Ingrédients
    Micro ELISA Plate(Dismountable)
    Reference Standard
    Concentrated Biotinylated Detection Ab (100×)
    Concentrated HRP Conjugate (100×)
    Reference Standard & Sample Diluent
    Biotinylated Detection Ab Diluent
    HRP Conjugate Diluent
    Concentrated Wash Buffer (25×)
    Substrate Reagent
    Stop Solution
    Plate Sealer
    Product Description
    Certificate of Analysis
    Matériel non inclus
    Microplate reader with 450nm wavelength filter
    High-precision transferpettor, EP tubes and disposable pipette tips
    37℃ Incubator
    Deionized or distilled water
    Absorbent paper
    Loading slot for Wash Buffer
    Featured
    Discover our best selling AGT Kit ELISA
    Top Product
    Discover our top product AGT Kit ELISA
  • Commentaires

    Information on standard material:
    The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).

    Information on reagents:
    Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.

    Information on antibodies:
    The provided antibodies and their host vary in different kits. All antibodies are affinity purified

    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.

    Volume d'échantillon
    50 µL
    Plaque
    Pre-coated
    Protocole
    This ELISA kit uses Competitive-ELISA as the method. The microtiter plate provided in this kit has been pre-coated with Ang-I. During the reaction, Ang-I in the sample or standard competes with a fixed amount of Ang-I on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Ang-I. Excess conjugate and unbound sample or standard are washed from the plate, and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spec trophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of Ang-I in the samples is then determined by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
    Stock
    4 °C/-20 °C
    Stockage commentaire
    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Antigène Voir toutes AGT Kits ELISA
    AGT (Angiotensinogen (serpin Peptidase Inhibitor, Clade A, Member 8) (AGT))
    Autre désignation
    AngiotensinI (Ang-I) (AGT Produits)
    Synonymes
    ANHU Kit ELISA, SERPINA8 Kit ELISA, AI265500 Kit ELISA, AngI Kit ELISA, AngII Kit ELISA, Aogen Kit ELISA, Serpina8 Kit ELISA, ANRT Kit ELISA, Ang Kit ELISA, PAT Kit ELISA, wu:fb62f06 Kit ELISA, wu:fj87b02 Kit ELISA, zgc:111892 Kit ELISA, AGT Kit ELISA, angt Kit ELISA, ANGT Kit ELISA, angiotensinogen Kit ELISA, angiotensinogen (serpin peptidase inhibitor, clade A, member 8) Kit ELISA, AGT Kit ELISA, Agt Kit ELISA, agt Kit ELISA
    Pathways
    Signalistation JAK/STAT, ACE Inhibitor Pathway, EGFR Signaling Pathway, Peptide Hormone Metabolism, Regulation of Systemic Arterial Blood Pressure by Hormones, Regulation of Lipid Metabolism by PPARalpha, Protein targeting to Nucleus, Feeding Behaviour, Monocarboxylic Acid Catabolic Process, Dicarboxylic Acid Transport, Positive Regulation of Response to DNA Damage Stimulus, Regulation of long-term Neuronal Synaptic Plasticity