Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

ADAM22 Kit ELISA

ADAM22 Reactivité: Humain Colorimetric Sandwich ELISA 0.156-10 ng/mL Plasma, Serum
N° du produit ABIN4993287
  • Antigène Voir toutes ADAM22 Kits ELISA
    ADAM22 (ADAM Metallopeptidase Domain 22 (ADAM22))
    Reactivité
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.156-10 ng/mL
    Seuil minimal de détection
    0.156 ng/mL
    Application
    ELISA
    Fonction
    The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of ADAM22 in human serum, plasma and other biological fluids
    Type d'échantillon
    Plasma, Serum
    Analytical Method
    Quantitative
    Specificité
    This kit recognizes natural and recombinantHumanADAM22. No significant cross-reactivity or interference between HumanADAM22 and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between HumanADAM22 and all the analogues.
    Sensibilité
    0.094 ng/mL
    Ingrédients
    Micro ELISA Plate
    Reference Standard
    Concentrated Biotinylated Detection Ab
    Concentrated HRP Conjugate
    Reference Standard & Sample Diluent
    Biotinylated Detection Ab Diluent
    HRP Conjugate Diluent
    Concentrated Wash Buffer (25×)
    Substrate Reagent
    Stop Solutio
    Plate Sealer
    Product Description
    Certificate of Analysis
    Matériel non inclus
    Microplate reader with 450nm wavelength filter
    High-precision transferpettor, EP tubes and disposable pipette tips
    37℃ Incubator
    Deionized or distilled water
    Absorbent paper
    Loading slot for Wash Buffer
    Featured
    Discover our best selling ADAM22 Kit ELISA
    Top Product
    Discover our top product ADAM22 Kit ELISA
  • Commentaires

    Information on standard material:
    The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).

    Information on reagents:
    Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.

    Information on antibodies:
    The provided antibodies and their host vary in different kits. All antibodies are affinity purified

    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.

    Volume d'échantillon
    100 µL
    Plaque
    Pre-coated
    Protocole
    This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to ADAM22. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for ADAM22and Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain ADAM22, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of ADAM22.You can calculate the concentration of ADAM22in the samples by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
    Stock
    4 °C/-20 °C
    Stockage commentaire
    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Antigène Voir toutes ADAM22 Kits ELISA
    ADAM22 (ADAM Metallopeptidase Domain 22 (ADAM22))
    Autre désignation
    A Disintegrin And Metalloprotease 22 (ADAM22) (ADAM22 Produits)
    Synonymes
    2900022I03Rik Kit ELISA, AI854032 Kit ELISA, MDC2 Kit ELISA, ADAM 22 Kit ELISA, mdc11b Kit ELISA, mdc2 Kit ELISA, a disintegrin and metallopeptidase domain 22 Kit ELISA, ADAM metallopeptidase domain 22 Kit ELISA, ADAM metallopeptidase domain 22 L homeolog Kit ELISA, Adam22 Kit ELISA, ADAM22 Kit ELISA, adam22.L Kit ELISA
Vous êtes ici:
Support technique