CLCF1 Kit CLIA
-
- Antigène Voir toutes CLCF1 Kits CLIA
- CLCF1 (Cardiotrophin-Like Cytokine Factor 1 (CLCF1))
-
Reactivité
- Souris
- Méthode de détection
- Chemiluminescent
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 31.25 pg/mL - 2000 pg/mL
- Seuil minimal de détection
- 31.25 pg/mL
- Application
- ELISA
- Type d'échantillon
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of Cardiotrophin Like Cytokine Factor 1 (CLCF1). No significant cross-reactivity or interference between Cardiotrophin Like Cytokine Factor 1 (CLCF1) and analogues was observed.
- Sensibilité
- 1 pg/mL
- Featured
- Discover our best selling CLCF1 Kit ELISA
- Top Product
- Discover our top product CLCF1 Kit ELISA
-
-
- Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Durée du test
- 2 - 3 h
- Plaque
- Pre-coated
- Protocole
- The microplate provided in this kit has been pre-coated with an antibody specific to Cardiotrophin Like Cytokine Factor 1 (CLCF1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Cardiotrophin Like Cytokine Factor 1 (CLCF1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Cardiotrophin Like Cytokine Factor 1 (CLCF1) level in the sample or standard.,
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cardiotrophin Like Cytokine Factor 1 (CLCF1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cardiotrophin Like Cytokine Factor 1 (CLCF1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Date de péremption
- 4-8 months
-
- Antigène Voir toutes CLCF1 Kits CLIA
- CLCF1 (Cardiotrophin-Like Cytokine Factor 1 (CLCF1))
- Autre désignation
- Cardiotrophin Like Cytokine Factor 1 (CLCF1 Produits)
- Synonymes
- clc Kit CLIA, nr6 Kit CLIA, bsf3 Kit CLIA, nnt1 Kit CLIA, ciss2 Kit CLIA, CLCF1 Kit CLIA, BSF-3 Kit CLIA, BSF3 Kit CLIA, CISS2 Kit CLIA, CLC Kit CLIA, NNT-1 Kit CLIA, NNT1 Kit CLIA, NR6 Kit CLIA, Bsf3 Kit CLIA, Clc Kit CLIA, cardiotrophin like cytokine factor 1 Kit CLIA, cardiotrophin-like cytokine factor 1 Kit CLIA, clcf1 Kit CLIA, CLCF1 Kit CLIA, Clcf1 Kit CLIA
- Sujet
-
Gene Name: Cardiotrophin Like Cytokine Factor 1
Gene Aliases: CLC, NR6, BSF3, CISS2, NNT1, Novel Neurotrophin-1, B Cell-Stimulating Factor-3
- ID gène
- 56708
- UniProt
- Q9QZM3
- Pathways
- Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response
-