Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

CEACAM1 Kit ELISA

CEACAM1 Reactivité: Humain Colorimetric Sandwich ELISA 0.78 ng/mL - 50 ng/mL Plasma, Serum, Tissue Homogenate
N° du produit ABIN6974128
  • Antigène Voir toutes CEACAM1 Kits ELISA
    CEACAM1 (Carcinoembryonic Antigen-Related Cell Adhesion Molecule 1 (CEACAM1))
    Reactivité
    • 6
    • 2
    • 2
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.78 ng/mL - 50 ng/mL
    Seuil minimal de détection
    0.78 ng/mL
    Application
    ELISA
    Fonction
    For the quantitative determination of human carcinoembryonic antigen-related cell adhesion molecule 1 (CEACAM1) concentrations in serum, plasma, tissue homogenates.
    Type d'échantillon
    Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of human CEACAM1. No significant cross-reactivity or interference between human CEACAM1 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between human CEACAM1 and all the analogues, therefore, cross reaction may still exist.
    Sensibilité
    0.195 ng/mL
    Ingrédients
    • Assay plate
    • Standard
    • HRP-avidin (100 x concentrate)
    • Biotin-antibody (100 x concentrate)
    • Sample Diluent
    • HRP-avidin Diluent
    • Biotin-antibody Diluent
    • Wash Buffer (25 x concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip
    Top Product
    Discover our top product CEACAM1 Kit ELISA
  • Indications d'application
    Optimal working dilution should be determined by the investigator.
    Volume d'échantillon
    100 μL
    Durée du test
    1 - 4.5 h
    Plaque
    Pre-coated
    Protocole
    1. Prepare reagents, samples and standards as instructed.
    2. Add 100 µL standard or sample to each well. Incubate 2 hours at 37 °C.
    3. Remove the liquid of each well, don't wash.
    4. Add 100 µL Biotin-antibody (1x) to each well. Incubate 1 hour at 37 °C.
    5. Aspirate and wash 3 times.
    6. Add 100 µL HRP-avidin (1x) to each well. Incubate 1 hour at 37 °C
    7. Aspirate and wash 5 times.
    8. Add 90 μL of TMB Substrate to each well. Incubate for 15-30 minutes at 37 °C. Protect from light.
    9. Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
    Préparation des réactifs
    1. Biotin-antibody (1x) - Centrifuge the vial before opening. Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of Biotin-antibody + 990 μL of Biotin-antibody Diluent.
    2. HRP-avidin (1x) - Centrifuge the vial before opening. HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-avidin + 990 μL of HRP-avidin Diluent.
    3. Wash Buffer (1x) - If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
    4. Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 50 ng/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 250 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (50 ng/mL). Sample Diluent serves as the zero standard (0 ng/mL).
    Note:
    • Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
    • Bring all reagents to room temperature (18-25 °C) before use for 30 min.
    • Prepare fresh standard for each assay. Use within 4 hours and discard after use.
    • Making serial dilution in the wells directly is not permitted.
    • Please carefully reconstitute Standards according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10 μL for once pipetting.
    • Distilled water is recommended to be used to make the preparation for reagents. Contaminated water or container for reagent preparation will influence the detection result.
    Préparation de l'échantillon
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
    Note:
    Recommend to dilute the serum or plasma samples with Sample Diluent (1:2) before test. The recommended dilution factor is for reference only. The optimal dilution factor should be determined by users according to their particular experiments.
    Précision du teste
    Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
    Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess.
    Restrictions
    For Research Use only
  • Stock
    4 °C,-20 °C
    Stockage commentaire
    Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date. May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If Biotin-antibody don't make recent use, better keep it store at HRP-avidin -20°C. Biotin-antibody Diluent Opened kit HRP-avidin Diluent Sample May be stored for up to 1 month at 2 - 8°C. Diluent Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
    Date de péremption
    6 months
  • Antigène Voir toutes CEACAM1 Kits ELISA
    CEACAM1 (Carcinoembryonic Antigen-Related Cell Adhesion Molecule 1 (CEACAM1))
    Autre désignation
    carcinoembryonic antigen-related cell adhesion molecule 1 (biliary glycoprotein) (CEACAM1 Produits)
    Synonymes
    BGP Kit ELISA, BGP1 Kit ELISA, BGPI Kit ELISA, CD66e Kit ELISA, CEA Kit ELISA, zeh0068 Kit ELISA, hm:zeh0068 Kit ELISA, CEACAM8 Kit ELISA, CEACAM1 Kit ELISA, MGC142545 Kit ELISA, BGPR Kit ELISA, Bgp Kit ELISA, CD66a Kit ELISA, Ccam1 Kit ELISA, Bgp1 Kit ELISA, C-CAM Kit ELISA, Cc1 Kit ELISA, Cea-1 Kit ELISA, Cea-7 Kit ELISA, Cea1 Kit ELISA, Cea7 Kit ELISA, Hv-2 Kit ELISA, Hv2 Kit ELISA, MHVR Kit ELISA, MHVR1 Kit ELISA, Mhv-1 Kit ELISA, bb-1 Kit ELISA, mCEA1 Kit ELISA, mmCGM1 Kit ELISA, mmCGM1a Kit ELISA, mmCGM2 Kit ELISA, carcinoembryonic antigen related cell adhesion molecule 1 Kit ELISA, carcinoembryonic antigen related cell adhesion molecule 5 Kit ELISA, carcinoembryonic antigen-related cell adhesion molecule 1 Kit ELISA, carcinoembryonic antigen-related cell adhesion molecule 6 Kit ELISA, CEACAM1 Kit ELISA, CEACAM5 Kit ELISA, ceacam1 Kit ELISA, Ceacam1 Kit ELISA, LOC101103343 Kit ELISA
    Sujet

    Abbreviation: CEACAM1

    Alias: BGP, BGP1, BGPI, CD66a antigen|antigen CD66|biliary glycoprotein adhesion molecule|carcinoembryonic antigen-related cell adhesion molecule 1

    UniProt
    P13688
Vous êtes ici:
Support technique