Humain Stem Cell Array G1

Reactivité: Humain AA Fluorometric Semi-Quantitative Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Lysate Glass Slide
N° du produit ABIN4955907
353,40 €
Plus frais de livraison 40,00 € et TVA
4 samples
Destination: France
Envoi sous 6 à 9 jours ouvrables

Aperçu rapide pour Humain Stem Cell Array G1 (ABIN4955907)

Reactivité

Humain

Méthode de détection

Fluorometric

Application

Antibody Array (AA)

Type d'échantillon

Plasma, Cell Culture Supernatant, Serum, Cell Lysate, Tissue Lysate

Analytical Method

Semi-Quantitative
  • Type de méthode

    Sandwich ELISA

    Fonction

    G-Series Human Stem Cell Array 1 Kit. Semi-quantitative measurement of 15 human stem cell biomarkers. Suitable for all liquid sample types.

    Specificité

    Alpha-fetoprotein, OCT-4, BMPR-IA (ALK-3), ALK-6 (BMPR-IB), Brachyury (Protein T), CD38, E-Cadherin, GATA4, hCG beta, Nanog, Nestin, PDX-1 (IPF1), SOX2, SOX17, VEGFR2

    Attributs du produit

    • High sensitivity and specificity
    • Low sample volume (10-100 μL per array)
    • Large dynamic range of detection
    • Compatible with most sample types
    • Test 4 or 8 samples on each slide
    • Suitable for high-throughput assays

    Ingrédients

    Cytokine Antibody Array glass slide (4 or 8 arrays per slide)
    Biotinylated Detection Antibodies
    Streptavidin-conjugated HiLytePlus™ 555 Fluor
    Blocking Buffer
    20X Wash Buffer I
    20X Wash Buffer II
    2X Cell Lysis Buffer
    G-Series Antibody Array accessories
    Accessories include: 16-well incubation chamber with gasket, protective cover, snap-on sides, adhesive film

    Matériel non inclus

    Small plastic boxes or containers
    Pipettors, pipette tips and other common lab consumables
    Orbital shaker or oscillating rocker
    Aluminum foil
    Gene microarray scanner or similar laser fluorescence scanner
  • Indications d'application

    Completely cover array area with sample or buffer during incubation. Avoid foaming during incubation steps. Perform all incubation and wash steps under gentle rocking or rotation. Cover the incubation chamber with adhesive film during incubation, particularly when incubation is more than 2 hours or <70 μL of sample or reagent is used. Several incubation steps such as step 6 (blocking), step 7 (sample incubation), step 10 (detection antibody incubation), or step 13 (Cy3 equivalent dyestreptavidin incubation) may be done overnight at 4 °C. Please make sure to cover the incubation chamber tightly to prevent evaporation.

    Commentaires

    The G-Series arrays feature fluorescent signal detection. The antibodies are spotted on glass slide solid supports and require a laser scanner for data collection.
    All G-Series arrays work on the sandwich ELISA principle, utilizing a matched pair of antibodies: an immobilized capture antibody and a corresponding biotinylated detection antibody.

    Volume d'échantillon

    100 μL

    Plaque

    Glass Slide

    Protocole

    1. Dry the glass slide
    2. Block array surface
    3. Incubate with Sample
    4. Incubate with Biotinylated Detection Antibody Cocktail
    5. Incubate with Streptavidin-Conjugated Fluor
    6. Disassemble the glass slide
    7. Scan with a gene microarray laser scanner
    8. Perform densitometry and analysis

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Do not touch the surface of the slides, as the microarray slides are very sensitive. Hold the slides by the edges only. Handle all buffers and slides with powder free gloves. Handle glass slide/s in clean environment. The G-Series slides do not have bar codes. To help distinguish one slide from another, transcribe the slide serial number from the slide bag to the back of the slide with a fine point permanent marker. Please write the number on the very bottom edge of the slide, taking care to avoid writing on the array well areas.

    Stock

    -20 °C

    Stockage commentaire

    For best results, store the entire kit frozen at -20°C upon arrival. Stored frozen, the kit will be stable for at least 6 months which is the duration of the product warranty period. Once thawed, store array slide(s) and 1X Blocking Buffer at -20°C and all other reagents undiluted at 4°C for no more than 3 months.