Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Galactose Assay Kit

BCA Cell Culture Supernatant, Milk, Plasma, Saliva, Serum, Urine
N° du produit ABIN1000309

Aperçu rapide pour Galactose Assay Kit (ABIN1000309)

Antigène

Galactose

Application

Biochemical Assay (BCA)

Type d'échantillon

Cell Culture Supernatant, Milk, Plasma, Saliva, Serum, Urine
  • Specificité

    10 μM

    Attributs du produit

    Use as little as 20 µL samples. Linear detection range in 96-well plate: 10 to 1000 µM galactose for colorimetric assays and 10 to 100 µM for fluorimetric assays.

    Ingrédients

    Assay Buffer: 10 mL. Enzyme Mix: 120 µL. Dye Reagent: 120 µL. Standard: 1 mL 10 mM Galactose.

    Matériel non inclus

    Pipetting devices, centrifuge tubes, clear flat-bottom 96-well plates, optical density plate reader, black 96-well plates and fluorescence plate reader.
  • Indications d'application

    Direct Assays: galactose in serum, plasma, urine, saliva, milk, culture medium and other biological samples.
    Drug Discovery/Pharmacology: effects of drugs on galactose metabolism.
    Food and Beverages: galactose in food and beverages products.

    Protocole

    Note: (1) glycerol and SH-containing reagents (e.g. µMercaptoethanol, dithiothreitol) are known to interfere in this assay and should be avoided in sample preparation. (2) This assay is based on a kinetic reaction. To ensure identical incubation time, addition of Working Reagent to standard and samples should be quick and mixing should be brief but thorough. Use of a multi-channel pipettor is recommended.
    1. Equilibrate all components to room temperature. During experiment, keep thawed Enzyme Mix in a refrigerator or on ice.
    2. Standards and samples: prepare 400 µL 1000 µMStandard by mixing 40 µL 10 mM standard with 360 µL dH2O. Dilute standard in dH2O. Transfer 20 µL standards and 20 µL samples into separate wells of a clear flat-bottom 96-well plate.
    3. Reaction. For each reaction well, mix 85 µL Assay Buffer, 1 µL Enzyme Mix (vortex briefly before pipetting), and 1 µL Dye Reagent in a clean tube. Transfer 80 µL Working Reagent into each reaction well. Tap plate to mix. Incubate 20 min at room temperature.
    4. Read optical density at 570nm (550-585nm).

    Préparation de l'échantillon

    Serum and plasma samples can be assayed directly. Milk samples should be cleared by mixing 600 µL milk with 100 µL 6 N HCl. Centrifuge 5 min at 14,000 rpm. Transfer 300 µL supernatant into a clean tube and neutralize with 50 µL 6 N NaOH. The neutralized supernatant is ready for assay (dilution factor n = 1.36)

    Calcul des résultats

    Subtract blank value (water, #8) from the standard values and plot the OD or RFU against standard concentrations.
    Conversions: 1 mM galactose equals 18 mg/dL, 0.018% or 180 ppm.

    Restrictions

    For Research Use only
  • Stock

    -20 °C
  • Sun, Zhao, Ye, Fan, Liu, Tan: "An investigation into the relationship between metabolic responses and energy regulation in antibody-producing cell." dans: Journal of microbiology and biotechnology, Vol. 23, Issue 11, pp. 1586-97, (2013) (PubMed).

  • Antigène

    Galactose

    Sujet

    Quantitative determination of galactose by colorimetric (570nm) or fluorimetric (530nm/590nm) methods.
    Procedure: 20 min.

    Galactose (C6H12O6) is a monosaccharide that is found in dairy products, sugar beets, gums and mucilages. It is also synthesized in mammals, where it forms part of glycolipids and glycoproteins in several tissues. It forms the disaccharide lactose when combined with glucose. Simple, direct and high-throughput assays for galactose determination find wide applications. This assay uses specific enzyme-coupled reactions to form a colored product. The color intensity at 570nm or fluorescence intensity at 530nm/585nm is directly proportional to the galactose concentration in the sample.