CPS1 Kit ELISA

Kit ELISA Humain CPS1, test Colorimetric pour la quantification de Humain CPS1. Il a été validé indépendamment.
N° du produit ABIN1125223

Aperçu rapide pour CPS1 Kit ELISA (ABIN1125223)

Antigène

Voir toutes CPS1 Kits ELISA
CPS1 (Carbamoyl-Phosphate Synthase 1, Mitochondrial (CPS1))

Épitope

Mitochondrial

Reactivité

  • 3
  • 1
  • 1
Humain

Méthode de détection

Colorimetric

Application

ELISA
  • Attributs du produit

    Homo sapiens,Human,Carbamoyl-phosphate synthase [ammonia], mitochondrial,Carbamoyl-phosphate synthetase I,CPSase I,CPS1,6.3.4.16

    Ingrédients

    Reagent (Quantity): Assay plate (1), Standard (2), Sample Diluent (1x20ml), Assay Diluent A (1x10ml), Assay Diluent B (1x10ml), Detection Reagent A (1x120µl), Detection Reagent B (1x120µl), Wash Buffer(25 x concentrate) (1x30ml), Substrate (1x10ml), Stop Solution (1x10ml)
  • Commentaires

    Gene Name: CPS1

    Volume d'échantillon

    100 μL

    Plaque

    Pre-coated

    Restrictions

    For Research Use only
  • Validation #103213 (ELISA)
    'Independent Validation' signe
    by
    Omary Lab, Department of Molecular & Integrative Physiology, University of Michigan Medical School
    No.
    #103213
    Date
    11.06.2018
    Antigène
    CPS1
    Numéro du lot
    7K295N
    Application validée
    ELISA
    Contrôle positif
    Human serum from patients with liver injury
    Contrôle négative
    Human serum from patients without liver injury
    Conclusion

    Passed, the CPS1 ELISA kit ABIN1125223 specifically detects the antigen in human serum samples.

    'Independent Validation' signe
    Validation Images
    Protocole
    Anticorps primaire
    Anticorps secondaire
    Full Protocol
    • Freeze human serum samples in aliquots until use. Dilute sera with PBS.
    • Allow all reagents to reach RT and prepare all the reagents, standard solutions and samples as instructed by the manufacturer.
    • Add 100µl of standard, blank or sample per well. Cover the plate. Incubate for 2h at 37°C.
    • Remove the liquid.
    • Add 100µl detection reagent A. Mix gently and cover the plate. Incubate for 1h at 37°C.
    • Aspirate liquid and wash the wells 3x with 400µl wash buffer. Let it sit for 1-2min. Remove liquid Completely at each step.
    • Add 100µl of detection reagent B. Cover the plate. Incubate for 1h at 37°C.
    • Wash well 5x with 400µl wash buffer.
    • Add 90µl substrate solution. Cover the plate. Incubate 15min at 37°C protected from light.
    • Add 50µl stop solution. Gently tap the plate to ensure thorough mixing.
    • Read absorbance at 450nm immediately.
    Notes
    • The purpose of this report is to validate the measurement of human CPS1 in human serum samples, since it has been published that CPS1 is released into serum during liver injury, while it is not detected in healthy human serum (Weerasinghe et al. (2014)).

    • To validate this ELISA, human serum samples previously validated to contain CPS1 by Western blotting were used. The signal in the positive controls samples (patients’ samples that contain high amount of CPS1 which was confirmed by Western blotting) was significantly higher than the blank whereas the signal from the negative control samples (healthy human sera in that CPS1 was not detected by Western blotting) was comparable to the baseline. 1:5, 1:25, or 1:125 diluted serum samples were tested as well.

    • CPS1 was not detected in the sera of healthy human by both western blotting and ELISA method (lane 1 and 2). However, it is highly increased in the sera of patients with acute liver failure and the signals were in a dilution-dependent manner (lane 3 to 11).

    • The standard curve for the assays reported were fitted with a 4-Parameter Logistic model. The calculated concentrations of standards were higher than expected, but it gave a good quality fits (R2=0.999). The results showed no CPS1 in the sera from healthy human, while it is highly increased in the sera from patients with liver injury, as expected. Although most of the samples were in the detection range, the calculated concentrations were highest in the most diluted samples.

  • Stock

    4 °C/-20 °C

    Stockage commentaire

    The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20 °C upon being received. The other reagents can be stored at 4 °C.
  • Antigène Voir toutes CPS1 Kits ELISA

    CPS1 (Carbamoyl-Phosphate Synthase 1, Mitochondrial (CPS1))

    Autre désignation

    CPS1

    Sujet

    Synonyms: Carbamoyl-phosphate synthase [ammonia], mitochondrial,Carbamoyl-phosphate synthetase I,CPS1,CPSase I,Homo sapiens,Human

    Pathways

    Response to Growth Hormone Stimulus, Cellular Glucan Metabolic Process
Vous êtes ici:
Chat with us!