Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

CX3CL1 Kit ELISA

Kit ELISA CX3CL1 Humain, Colorimetric test pour la quantification de Humain CX3CL1.
N° du produit ABIN1846888
834,40 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 7 à 13 jours ouvrables

Aperçu rapide pour CX3CL1 Kit ELISA (ABIN1846888)

Antigène

Voir toutes CX3CL1 Kits ELISA
CX3CL1 (Chemokine (C-X3-C Motif) Ligand 1 (CX3CL1))

Reactivité

  • 27
  • 23
  • 23
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Gamme de detection

0.16 ng/mL - 10 ng/mL

Application

ELISA

Type d'échantillon

Plasma, Serum
  • Seuil minimal de détection

    0.16 ng/mL

    Fonction

    This kit is based on sandwich enzyme-linked immuno-sorbent assay technology.

    Analytical Method

    Quantitative

    Sensibilité

    0.1 ng/mL

    Ingrédients

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Matériel non inclus

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Volume d'échantillon

    100 µL

    Plaque

    Pre-coated

    Protocole

    This kit is based on sandwich enzyme-linked immuno-sorbent assay technology. An antibody is pre-coated onto a 96-well plate. Standards, test samples, and biotin-conjugated reagent are added to the wells and incubated. The HRP-conjugated reagent is then added, and the whole plate is incubated. Unbound conjugates are removed using wash buffer at each stage. TMB substrate is used to quantify the HRP enzymatic reaction. After TMB substrate is added, only wells that contain sufficient CX3CL1 will produce a blue coloured product, which then changes to yellow after adding the acidic stop solution. The intensity of the yellow colour is proportional to the CX3CL1 amount bound on the plate. The Optical Density (OD) is measured spectrophotometrically at 450 nm in a microplate reader, from which the concentration of CX3CL1 can be calculated.

    Préparation des réactifs

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • 1) Standard: Prepare the standard with the recommended volume of Standard Diluent Buffer, to make the standard solution. Then use the Standard Diluent buffer to carry out serial dilutions of the standard solution, as instructed in the Protocol.
    • 2) Wash Buffer: Dilute the concentrated Wash Buffer with distilled water, as instructed in the Protocol.
    • 3) Detection Reagent Preparation: Calculate the total volume of working solution required. Dilute Detection Reagent A and Detection Reagent B with Diluent A and Diluent B, respectively, at 1:100.

    Procédure de l'essai

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • 1) Set standard, test samples and control wells.
    • 2) Aliquot 100 μL of diluted standard into the standard wells.
    • 3) Aliquot 100 μL of Standard Diluent buffer into control (zero) well.
    • 4) Aliquot 100 μL of diluted samples into the sample wells. Incubate for 90 mins at 37 °C.
    • 5) Aliquot 100 μL of Detection Reagent A to each well. Incubate for 1 hr at 37 °C.
    • 6) Wash 3 times.
    • 7) Aliquot 100 μL of Detection Reagent B to each well. Incubate for 30 mins at 37 °C.
    • 8) Wash 5 times.
    • 9) Aliquot 90 μL of TMB Substrate to each well. Incubate for 10-20 mins at 37 °C.
    • 10) Aliquot 50 μL of Stop Solution.
    • 11) Measure the OD at 450 nm.

    Calcul des résultats

    For calculation, average the O.D.450 duplicate readings for each reference standard and each sample and substract the average control (zero) O.D.450 reading. The standard curve can be plotted as the relative O.D.450 of each reference standard solution (Y) vs. the respective concentration of each standard solution (X). The CX3CL1 concentration of the samples can be interpolated from the standard curve.

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Fractalkine (CX3CL1) were were tested 20 times on one plate, respectively.

    Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Fractalkine (CX3CL1) were tested on 3 different plates, 8 replicates in each plate.

    CV (%) = (Standard Deviation / mean) x 100

    Intra-Assay: CV<10%

    Inter-Assay: CV<10%

    Restrictions

    For Research Use only
  • Stock

    4 °C

    Stockage commentaire

    Shipped at 4°C. Upon receipt, store the kit according to the storage instruction in the kit's manual.The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5% within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Date de péremption

    6 months
  • Antigène Voir toutes CX3CL1 Kits ELISA

    CX3CL1 (Chemokine (C-X3-C Motif) Ligand 1 (CX3CL1))

    Autre désignation

    Fractalkine

    Pathways

    Synaptic Membrane
Vous êtes ici:
Chat with us!