Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

CXCL14 Kit ELISA

CXCL14 Reactivité: Humain Colorimetric Sandwich ELISA 700-21000 pg/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN1979502
  • Antigène Voir toutes CXCL14 Kits ELISA
    CXCL14 (Chemokine (C-X-C Motif) Ligand 14 (CXCL14))
    Reactivité
    • 5
    • 4
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    700-21000 pg/mL
    Seuil minimal de détection
    700 pg/mL
    Application
    ELISA
    Fonction
    Human CXCL14 (BRAK) ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Type d'échantillon
    Plasma, Cell Culture Supernatant, Serum
    Analytical Method
    Quantitative
    Specificité
    This ELISA antibody pair detects human CXCL14. Other species not determined.
    Attributs du produit
    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data
    Ingrédients
    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate
    Matériel non inclus
    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
    Featured
    Discover our best selling CXCL14 Kit ELISA
    Top Product
    Discover our top product CXCL14 Kit ELISA
  • Indications d'application
    Recommended Dilution for serum and plasma samples3 fold
    Volume d'échantillon
    100 μL
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.
    Préparation des réactifs
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. 2. Sample dilution: If your samples need to be diluted, 1x Assay Diluent D (Item K) should be used for dilution of serum/plasma /culture supernatants/urine. Human CXCL14 ELISA Kit Protocol 4 Suggested dilution for normal serum/plasma: 3 fold. Please note that levels of mL of Wash Buffer Concentrate into deionized or distilled water to yield 400 mL of 1x Wash Buffer. 6. Briefly spin the Detection Antibody vial (Item F) before use. Add 100 µl of 1x Assay Diluent B (Item E) into the vial to prepare a detection antibody concentrate. Pipette up and down to mix gently (the concentrate can be stored at 4 °C for 5 days). The detection antibody concentrate should be diluted 80-fold with 1x Assay Diluent B and used in step 4 of Part VI Assay Procedure. 7. Briefly spin the HRP-Streptavidin concentrate vial (Item G) and pipette up and down to mix gently before use. HRP-Streptavidin concentrate should be diluted 200-fold with 1x Assay Diluent B (Item E). For example: Briefly spin the vial (Item G) and pipette up and down to mix gently . Add 50 µl of HRP-Streptavidin concentrate into a tube with 10 mL 1x Assay Diluent B to prepare a 200-fold diluted HRP-Streptavidin solution (don't store the diluted solution for next day use). Mix well.
    Procédure de l'essai
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate. 2. Add 100 µL of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or overnight at 4 °C with gentle shaking. 3. Discard the solution and wash 4 times with 1x Wash Solution. Wash by filling each well with Wash Buffer (300 µl) using a multi-channel Human CXCL14 ELISA Kit Protocol 6 Pipette or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels. 4. Add 100 µl of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking. 5. Discard the solution. Repeat the wash as in step 3. 6. Add 100 µl of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking. 7. Discard the solution. Repeat the wash as in step 3. 8. Add 100 µl of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking. 9. Add 50 µl of Stop Solution (Item I) to each well. Read at 450 nm immediately.
    Calcul des résultats

    Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the average zero standard optical density. Plot the standard curve on log-log graph paper or using Sigma plot software, with standard concentration on the x-axis and absorbance on the y-axis. Draw the best-fit straight line through the standard points.

    Précision du teste
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    Avoid repeated freeze-thaw cycles.
    Stock
    -20 °C
    Stockage commentaire
    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
    Date de péremption
    6 months
  • Antigène Voir toutes CXCL14 Kits ELISA
    CXCL14 (Chemokine (C-X-C Motif) Ligand 14 (CXCL14))
    Autre désignation
    CXCL14 (CXCL14 Produits)
    Synonymes
    BMAC Kit ELISA, BRAK Kit ELISA, KEC Kit ELISA, KS1 Kit ELISA, MIP-2g Kit ELISA, MIP2G Kit ELISA, NJAC Kit ELISA, SCYB14 Kit ELISA, 1110031L23Rik Kit ELISA, 1200006I23Rik Kit ELISA, AI414372 Kit ELISA, Kec Kit ELISA, MIP2gamma Kit ELISA, Scyb14 Kit ELISA, bolekine Kit ELISA, scyba Kit ELISA, fb67g04 Kit ELISA, wu:fb67g04 Kit ELISA, JSC Kit ELISA, bmac Kit ELISA, brak Kit ELISA, kec Kit ELISA, ks1 Kit ELISA, mip-2g Kit ELISA, mip2g Kit ELISA, njac Kit ELISA, scyb14 Kit ELISA, CXCL14 Kit ELISA, DKFZp469J175 Kit ELISA, C-X-C motif chemokine ligand 14 Kit ELISA, chemokine (C-X-C motif) ligand 14 Kit ELISA, chemokine (C-X-C motif) ligand 14 L homeolog Kit ELISA, CXCL14 Kit ELISA, Cxcl14 Kit ELISA, cxcl14 Kit ELISA, cxcl14.L Kit ELISA
    ID gène
    9547
    UniProt
    O95715
    Pathways
    Autophagy
Vous êtes ici:
Support technique