Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Osteocalcin Kit ELISA

Ce kit ELISA Colorimetric est conçu pour la mesure quantitative de Humain Osteocalcin.
N° du produit ABIN2648801

Aperçu rapide pour Osteocalcin Kit ELISA (ABIN2648801)

Antigène

Voir toutes Osteocalcin (BGLAP) Kits ELISA
Osteocalcin (BGLAP)

Reactivité

  • 10
  • 8
  • 7
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
Humain

Méthode de détection

Colorimetric

Application

ELISA

Type d'échantillon

Serum, Plasma
  • Sensibilité

    .31 ng/ml

    Attributs du produit

    Human Osteocalcin ELISA Assay Kit (enzyme-linked immunoassay kit) is intended for the quantitative determination of both human osteocalcin (1-49) and osteocalcin (1-43) (also referred as N-terminal & mid-regional osteocalcin) levels in test samples). Human Osteocalcin ELISA Assay Kit is for research use only and not to be used in diagnostic procedures.
  • Indications d'application

    Optimal working dilution should be determined by the investigator.

    Volume d'échantillon

    25 μL

    Durée du test

    1.5 h

    Protocole

    Human Osteocalcin ELISA Assay Kit is designed, developed and produced for the quantitative measurement of of human osteocalcin (1-49) and (1-43) in serum or plasma sample. The assay utilizes the two-site "sandwich" technique with two selected antibodies that bind to different epitopes of human osteocalcin. Assay standards, controls and samples are added directly to wells of a microtiter plate that is coated with streptavidin. Subsequently, a mixture of biotinylated human osteocalcin N-terminal region specific polyclonal antibody and a peroxidase labeled human osteocalcin 20 - 43 region specific monoclonal antibody is added to each well. After the first incubation period, a "sandwich" of "biotinylated antibody - human osteocalcin - HRP-monoclonal antibody" is formed and this immunocomplex is also captured to the wall of microtiter plate via a streptavidin-biotin affinity binding. The unbound monoclonal antibodies and buffer matrix are removed in the subsequent washing step. A substrate solution in a timed reaction is then measured in a spectrophotometric microplate reader. The enzymatic activity of the immunocomplex bound to the wall of each microtiter well is directly proportional to the amount of human osteocalcin in a test sample. A standard curve is generated by plotting the absorbance versus the respective human osteocalcin concentration for each standard on point-to-point or 4 parameter curve fit. The concentration of human osteocalcin in test samples is determined directly from this standard curve.

    Restrictions

    For Research Use only
  • Stock

    4 °C
  • Antigène Voir toutes Osteocalcin (BGLAP) Kits ELISA

    Osteocalcin (BGLAP)

    Autre désignation

    Osteocalcin
Vous êtes ici:
Chat with us!