Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Transferrin Kit ELISA

TF Reactivité: Humain Colorimetric Sandwich ELISA 937.50-60000 pg/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN3198488
  • Antigène Voir toutes Transferrin (TF) Kits ELISA
    Transferrin (TF)
    Reactivité
    • 7
    • 5
    • 4
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    937.50-60000 pg/mL
    Seuil minimal de détection
    937.50 pg/mL
    Application
    ELISA
    Fonction
    This assay employs the quantitative sandwich enzyme immunoassay technique for quantitative detection.
    Type d'échantillon
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Quantitative
    Specificité
    Transferrin / TF, Human
    Sensibilité
    2.82 pg/mL
    Ingrédients
    Plate, Standard, Diluent
    Matériel non inclus
    Microplate reader capable of measuring absorbance at 450 nm, with correction wavelength set at 570 nm or 630 nm.
    Pipettes and pipette tips.
    50 μL to 300 μL adjustable multichannel micropipette with disposable tips.
    Multichannel micropipette reservoir.
    Beakers, flasks, cylinders necessary for preparation of reagents.
    Deionized or distilled water.
    Polypropylene test tubes for dilution.
    Featured
    Discover our best selling TF Kit ELISA
    Top Product
    Discover our top product TF Kit ELISA
  • Volume d'échantillon
    100 μL
    Durée du test
    3 - 4 h
    Plaque
    Pre-coated
    Restrictions
    For Research Use only
  • Buffer
    Buffer contains: 0.02 % sodium azide
    Agent conservateur
    Sodium azide
    Précaution d'utilisation
    This product contains Sodium azide: a POISONOUS AND HAZARDOUS SUBSTANCE which should be handled by trained staff only.
    Conseil sur la manipulation
    Intended for research use only and are not for use in diagnostic or therapeutic procedures.
    Treat all chemicals with caution because they can be potentially hazardous.
    It is recommended that this product is handled only by persons who have been trained in laboratory techniques and in accordance with the principles of good laboratory practice. Wear personal protection equipment such as laboratory coat, safety glasses and gloves.
    Avoid direct contact with skin or eyes. Wash immediately with water in the case of contact with skin or eyes. Avoid contact of skin or mucous membranes with kit reagents or specimens. See material safety data sheet(s) for specific advice.
    Pure water or deionized water must be used for reagent preparation.
    The Stop Solution provided with this kit is an acid solution. Wear personal protection equipment with caution.
    Do not expose kit reagents to strong light during storage and incubation.
    Rubber or disposable latex gloves should be worn while handling kit reagents or specimens.
    Avoid contact of substrate solution with oxidizing agents and metal.
    Avoid splashing or generation of aerosols.
    Use disposable pipette tips and/or pipettes to avoid microbial or cross-contamination of reagents or specimens which may invalidate the test.
    Use clean, dedicated reagent trays for dispensing the conjugate and substrate reagent.
    Exposure to acid inactivates the HRP and antibody conjugate.
    Substrate solution must be warmed to room temperature prior to use.
    Decontaminate and dispose specimens and all potentially contaminated materials as they could contain infectious agents. The preferred method of decontamination is autoclaving for a minimum of 1 hour at 121.5 °C.
    Liquid wastes not containing acid and neutralized waste may be mixed with sodium hypochlorite in volumes such that the final mixture contains 1.0 % sodium hypochlorite. Allow 30 minutes for effective decontamination. Liquid waste containing acid must be neutralized prior to the addition of sodium hypochlorite.
    All reagents including microplate, samples, standards and working solution should be warmed to room temperature before use.
    To obtain accurate results, using adhesive film to seal the plate during incubation is suggested.
    It is recommended that all samples and standards be assayed in duplicate.
    Avoid foaming when mixing or reconstituting solutions containing protein.
    To avoid cross-contamination, use separate reservoirs for each reagent and change pipette tips between each standard, sample and reagent.
    When using an automated plate washer, adding a 30 seconds soak period before washing step and/or rotating the plate between wash steps may improve assay precision.
    When pipetting reagents, maintain a consistent order of addition from well-to-well.
    Keep Substrate solution protected from direct strong light. Substrate Solution should turn to gradations of blue after a proper color development.
    Read absorbance within 30 minutes after adding stop solution.
    Take care not to scratch the inner surface of the microwells.
    Stock
    4 °C
    Stockage commentaire
    Store kit reagents between 2 and 8 °C. Immediately after use remaining reagents should be returned to cold storage (2 to 8 °C).
    Expiry of the kit and reagents is stated on labels. Expiration date of the kit components can only be guaranteed if the components are stored properly, and if, in case of repeated use of one component, this reagent is not contaminated by the first handling.
    Unopened Kit: Store at 2 - 8 °C (See expiration date on the label).
    Opened/Reconstituted Reagents: Up to 1 month at 2 - 8 °C.
    Reconstituted Standard: Up to 1 month at ≤ -20 °C in a manual defrost freezer. Avoid repeated freeze-thaw cycles.
    Microplate Wells: Up to 1 month at 2 - 8 °C. Return unused strips to the foil pouch containing the desiccant pack, reseal along entire edge to maintain plate integrity. Provided this is within the expiration date of the kit
  • Antigène Voir toutes Transferrin (TF) Kits ELISA
    Transferrin (TF)
    Autre désignation
    Transferrin / TF (TF Produits)
    Synonymes
    ltf Kit ELISA, pro1557 Kit ELISA, pro2086 Kit ELISA, mgc107777 Kit ELISA, LOC692564 Kit ELISA, TF Kit ELISA, LOC100144362 Kit ELISA, tf Kit ELISA, LTF Kit ELISA, TFEW Kit ELISA, conalbumin Kit ELISA, tf-b Kit ELISA, MGC64306 Kit ELISA, PRO1557 Kit ELISA, PRO2086 Kit ELISA, TFQTL1 Kit ELISA, AI266983 Kit ELISA, Cd176 Kit ELISA, HP Kit ELISA, Tf Kit ELISA, Tfn Kit ELISA, hpx Kit ELISA, Trf Kit ELISA, cb285 Kit ELISA, gavi Kit ELISA, id:ibd3238 Kit ELISA, id:ibd3525 Kit ELISA, sb:cb285 Kit ELISA, wu:fb57g06 Kit ELISA, wu:fb62h02 Kit ELISA, wu:fb63h10 Kit ELISA, wu:fb64h10 Kit ELISA, zgc:112154 Kit ELISA, 143958_at Kit ELISA, CG6186 Kit ELISA, Dmel\\CG6186 Kit ELISA, TSF1 Kit ELISA, anon-EST:Posey265 Kit ELISA, tsf1 Kit ELISA, Pro-TRH Kit ELISA, IL-5 Kit ELISA, STF I Kit ELISA, TRF1 Kit ELISA, sTF1 Kit ELISA, sTf Kit ELISA, tf1 Kit ELISA, transferrin Kit ELISA, serotransferrin Kit ELISA, transferrin (ovotransferrin) Kit ELISA, transferrin L homeolog Kit ELISA, melanotransferrin Kit ELISA, transferrin-a Kit ELISA, Transferrin 1 Kit ELISA, thyrotropin releasing hormone Kit ELISA, interleukin 5 Kit ELISA, TF Kit ELISA, LOC477072 Kit ELISA, tf Kit ELISA, Tf Kit ELISA, LOC100144362 Kit ELISA, tf.L Kit ELISA, LOC5575625 Kit ELISA, Trf Kit ELISA, tfa Kit ELISA, Tsf1 Kit ELISA, TRH Kit ELISA, IL5 Kit ELISA, LOC101085148 Kit ELISA, LOC100726872 Kit ELISA, trf Kit ELISA
    Sujet
    Transferrin (TF) is a secreted protein which belongs to the transferrin family. It is expressed by the liver and secreted in plasma. TF has a molecular weight of around 80 KDa and contains two specific high-affinity Fe (III) binding sites.
    ID gène
    7018
    NCBI Accession
    NM_001063
    UniProt
    P02787
    Pathways
    Transition Metal Ion Homeostasis