Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

CCL4 Kit ELISA

Kit ELISA CCL4 Boeuf (Vache), Colorimetric test pour la quantification de Boeuf (Vache) CCL4.
N° du produit ABIN4881480
790,36 €
Plus frais de livraison 40,00 € et TVA
Destination: France
Envoi sous 35 à 47 jours ouvrables

Aperçu rapide pour CCL4 Kit ELISA (ABIN4881480)

Antigène

Voir toutes CCL4 Kits ELISA
CCL4 (Chemokine (C-C Motif) Ligand 4 (CCL4))

Reactivité

  • 22
  • 20
  • 18
  • 9
  • 8
  • 8
  • 6
  • 4
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
Boeuf (Vache)

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Application

ELISA
  • Fonction

    Bovine MIP-1 beta (CCL4) ELISA Kit.

    Analytical Method

    Quantitative

    Specificité

    The antibody pair provided in this kit recognizes Bovine MIP-1 beta (CCL4)

    Attributs du produit

    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data

    Ingrédients

    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate< div class='ty-product-feature'>< div class='ty-product-feature__label'>Other Materials Required< div class='ty-product-feature__value'>
      • Distilled or deionized water
      • Precision pipettes to deliver 2 μl to 1 μl volumes
      • Adjustable 1-25 μl pipettes for reagent preparation
      • 100 μl and 1 liter graduated cylinders
      • Tubes to prepare standard and sample dilutions
      • Absorbent paper
      • Microplate reader capable of measuring absorbance at 450nm
      • Log-log graph paper or computer and software for ELISA data analysis
      ,
      • Pre-Coated 96-well Strip Microplate
      • Wash Buffer
      • Stop Solution
      • Assay Diluent(s)
      • Lyophilized Standard
      • Biotinylated Detection Antibody
      • Streptavidin-Conjugated HRP
      • TMB One-Step Substrate< div class='ty-product-feature'>< div class='ty-product-feature__label'>Other Materials Required< div class='ty-product-feature__value'>
        • Distilled or deionized water
        • Precision pipettes to deliver 2 μl to 1 μl volumes
        • Adjustable 1-25 μl pipettes for reagent preparation
        • 100 μl and 1 liter graduated cylinders
        • Tubes to prepare standard and sample dilutions
        • Absorbent paper
        • Microplate reader capable of measuring absorbance at 450nm
        • Log-log graph paper or computer and software for ELISA data analysis

    Matériel non inclus

    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
  • Indications d'application

    Optimal working dilution should be determined by the investigator.

    Plaque

    Pre-coated

    Protocole

    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4°C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.

    Restrictions

    For Research Use only
  • Stock

    -20 °C

    Stockage commentaire

    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened Microplate Wells or reagents may be store for up to 1 month at 2° to 8°C. Return unused wells to the pouch containing desiccant pack, reseal along entire edge. Note: the kit can be used within one year if the whole kit is stored at -20°C.

    Date de péremption

    6 months
  • Antigène Voir toutes CCL4 Kits ELISA

    CCL4 (Chemokine (C-C Motif) Ligand 4 (CCL4))

    Autre désignation

    MIP-1 beta

    Sujet

    Gene Symbols: Macrophage inflammatory protein 1-alpha
Vous êtes ici:
Chat with us!