Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

SLAMF8 Kit ELISA

Ce kit ELISA Humain SLAMF8 est un kit ELISA Colorimetric conçu pour quantifier Humain SLAMF8.
N° du produit ABIN4881962

Aperçu rapide pour SLAMF8 Kit ELISA (ABIN4881962)

Antigène

Voir toutes SLAMF8 Kits ELISA
SLAMF8 (SLAM Family Member 8 (SLAMF8))

Reactivité

  • 1
  • 1
Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Application

ELISA

Type d'échantillon

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Lysate
  • Fonction

    Custom Human BLAME (SLAMF8) ELISA Kit.

    Analytical Method

    Quantitative

    Specificité

    The antibody pair provided in this kit recognizes Human BLAME (SLAMF8)

    Attributs du produit

    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data

    Ingrédients

    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate

    Matériel non inclus

    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
  • Volume d'échantillon

    100 μL

    Plaque

    Pre-coated

    Protocole

    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.

    Restrictions

    For Research Use only
  • Stock

    -20 °C

    Stockage commentaire

    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.

    Date de péremption

    6 months
  • Antigène Voir toutes SLAMF8 Kits ELISA

    SLAMF8 (SLAM Family Member 8 (SLAMF8))

    Autre désignation

    BLAME

    ID gène

    56833

    UniProt

    Q9P0V8