Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

LRRC4 Kit ELISA

Kit ELISA Humain LRRC4, test Colorimetric pour la quantification de Humain LRRC4.
N° du produit ABIN4883655

Aperçu rapide pour LRRC4 Kit ELISA (ABIN4883655)

Antigène

Tous les produits LRRC4
LRRC4 (Leucine Rich Repeat Containing 4 (LRRC4))

Reactivité

Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Application

ELISA

Type d'échantillon

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Lysate
  • Fonction

    Custom Human LRRC4 ELISA Kit.

    Analytical Method

    Quantitative

    Attributs du produit

    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data

    Ingrédients

    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate

    Matériel non inclus

    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
  • Volume d'échantillon

    100 μL

    Plaque

    Pre-coated

    Protocole

    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.

    Restrictions

    For Research Use only
  • Stock

    -20 °C

    Stockage commentaire

    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.

    Date de péremption

    6 months
  • Antigène Tous les produits LRRC4

    LRRC4 (Leucine Rich Repeat Containing 4 (LRRC4))

    Autre désignation

    LRRC4

    ID gène

    64101

    UniProt

    Q9HBW1

    Pathways

    Synaptic Membrane
Vous êtes ici: