Histocompatibility 60a Kit ELISA
Aperçu rapide pour Histocompatibility 60a Kit ELISA (ABIN4885533)
Antigène
Tous les produits Histocompatibility 60a (H60A)Reactivité
Méthode de détection
Type de méthode
Gamme de detection
Application
Type d'échantillon
-
-
Seuil minimal de détection
- 82 pg/mL
-
Fonction
- Mouse H60 ELISA Kit for Cell Culture Supernatants, Plasma, and Serum samples.
-
Analytical Method
- Quantitative
-
Specificité
- Cross Reactivity: This ELISA kit shows no cross-reactivity with the following cytokines tested: Mouse BAFF R, BTC, C5a, CCL6, CD48, CD6, CD80, Chemerin, Clusterin, Cystatin C, DAN, DLL4, EDAR, Endocan, Fetuin A, IL-33, IL-7 R alpha, Kremen-1, Limitin, Lipocalin-2, LOX-1, Lungkine, Marapsin, MBL-2, Meteorin, Nope, NOV, Osteoactivin, OX40 Ligand, P-Cadherin, Periostin, PlGF-2, Progranulin, Prostasin, Renin 1, Testican 3, TIM-1, TRAIL, Tryptase epsilon.
-
Attributs du produit
-
- Strip plates and additional reagents allow for use in multiple experiments
- Quantitative protein detection
- Establishes normal range
- The best products for confirmation of antibody array data
-
Ingrédients
-
- Pre-Coated 96-well Strip Microplate
- Wash Buffer
- Stop Solution
- Assay Diluent(s)
- Lyophilized Standard
- Biotinylated Detection Antibody
- Streptavidin-Conjugated HRP
- TMB One-Step Substrate
- Pre-Coated 96-well Strip Microplate
- Wash Buffer
- Stop Solution
- Assay Diluent(s)
- Lyophilized Standard
- Biotinylated Detection Antibody
- Streptavidin-Conjugated HRP
- TMB One-Step Substrate
-
Matériel non inclus
-
- Distilled or deionized water
- Precision pipettes to deliver 2 μL to 1 μL volumes
- Adjustable 1-25 μL pipettes for reagent preparation
- 100 μL and 1 liter graduated cylinders
- Tubes to prepare standard and sample dilutions
- Absorbent paper
- Microplate reader capable of measuring absorbance at 450nm
- Log-log graph paper or computer and software for ELISA data analysis
-
-
-
-
Indications d'application
- Suggested Plasma Dilution: 2 fold
-
Plaque
- Pre-coated
-
Protocole
-
- Prepare all reagents, samples and standards as instructed in the manual.
- Add 100 μL of standard or sample to each well.
- Incubate 2.5 h at RT or O/N at 4 °C.
- Add 100 μL of prepared biotin antibody to each well.
- Incubate 1 h at RT.
- Add 100 μL of prepared Streptavidin solution to each well.
- Incubate 45 min at RT.
- Add 100 μL of TMB One-Step Substrate Reagent to each well.
- Incubate 30 min at RT.
- Add 50 μL of Stop Solution to each well.
- Read at 450 nm immediately.
-
Restrictions
- For Research Use only
-
-
-
Stock
- -20 °C
-
Stockage commentaire
-
May be stored for up to 6 months at 2° to 8°C from the date of shipment. Opened Microplate Wells or reagents may be store for up to 1 month at 2° to 8°C. Return unused wells to the pouch containing desiccant pack, reseal along entire edge. Reconstituted standard can be stored at -80°C for up to 1 week.
Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles. -
Date de péremption
- 6 months
-
-
- Histocompatibility 60a (H60A)
-
Autre désignation
- H60
-
Sujet
-
Gene Symbols: H60A, H60
Protein Name (Synonyms): Histocompatibility antigen 60a
-
ID gène
- 15101
-
UniProt
- Q3TDZ7
Antigène Tous les produits Histocompatibility 60a (H60A)
-