Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

TUBB Kit ELISA

TUBB Reactivité: Humain, Rat, Souris Colorimetric Sandwich ELISA 0.31 ng/mL - 20 ng/mL Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
N° du produit ABIN4948104
  • Antigène Voir toutes TUBB Kits ELISA
    TUBB (Tubulin, beta (TUBB))
    Reactivité
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Humain, Rat, Souris
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.31 ng/mL - 20 ng/mL
    Seuil minimal de détection
    0.31 ng/mL
    Application
    ELISA
    Fonction
    ELISA Kit for Tubulin Beta (TUBb)
    Type d'échantillon
    Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificité

    This assay has high sensitivity and excellent specificity for detection of Tubulin Beta (TUBb).
    No significant cross-reactivity or interference between Tubulin Beta (TUBb) and analogues was observed.

    Sensibilité
    0.112 ng/mL
    Ingrédients
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • Reagent Diluent (if Detection Reagent is lyophilized)
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30 x concentrate)
    • Instruction manual
    Featured
    Discover our best selling TUBB Kit ELISA
    Top Product
    Discover our top product TUBB Kit ELISA
  • Indications d'application
    • Limited by the current condition and scientific technology, we cannot completely conduct the comprehensive identification and analysis on the raw material provided by suppliers. So there might be some qualitative and technical risks to use the kit.
    • The final experimental results will be closely related to validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available.
    • Kits from different batches may be a little different in detection range, sensitivity and color developing time.
    • Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
    • Protect all reagents from strong light during storage and incubation. All the bottle caps of reagents should be covered tightly to prevent the evaporation and contamination of microorganism.
    • There may be some foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
    • Wrong operations during the reagents preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
    • Even the same operator might get different results in two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before assay for each batch is recommended.
    • Each kit has been strictly passed Q.C test. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipments. Intra-assay variance among kits from different batches might arise from above factors, too.
    • Kits from different manufacturers for the same item might produce different results, since we have not compared our products with other manufacturers.
    Commentaires

    Information on standard material:
    The standard might be recombinant protein or natural protein, that will depend on the specific kit. Moreover, the expression system is E.coli or yeast or mammal cell. There is 0.05% proclin 300 in the standard as preservative.

    Information on reagents:
    The stop solution used in the kit is sulfuric acid with concentration of 1 mol/L. And the wash solution is TBS. The standard diluent contains 0.02 % sodium azide, assay diluent A and assay diluent B contain 0.01% sodium azide. Some kits can contain is BSA in them.

    Information on antibodies:
    The provided antibodies and their host vary in different kits.

    Volume d'échantillon
    100 μL
    Durée du test
    3 h
    Plaque
    Pre-coated
    Protocole
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Tubulin Beta (TUBb). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Tubulin Beta (TUBb). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Tubulin Beta (TUBb), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Tubulin Beta (TUBb) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    Préparation des réactifs
    1. Bring all kit components and samples to room temperature (18-25 °C) before use. If the kit will not be used up in one time, please only take out strips and reagents for present experiment, and leave the remaining strips and reagents in required condition.
    2. Standard - Reconstitute the Standard with 1.0 mL of Standard Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). The concentration of the standard in the stock solution is 40 ng/mL. Firstly dilute the stock solution to 20 ng/mL and the diluted standard serves as the highest standard (20 ng/mL). Then prepare 7 tubes containing 0.5 mL Standard Diluent and use the diluted standard to produce a double dilution series. Mix each tube thoroughly before the next transfer. Set up 7 points of diluted standard such as 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.312 ng/mL, and the last microcentrifuge tube with Standard Diluent is the blank as 0 ng/mL.
    3. Detection Reagent A and Detection Reagent B - If lyophilized reconstitute the Detection Reagent A with 150μL of Reagent Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). Briefly spin or centrifuge the stock Detection A and Detection B before use. Dilute them to the working concentration 100-fold with Assay Diluent A and B, respectively.
    4. Wash Solution - Dilute 20 mL of Wash Solution concentrate (30x) with 580 mL of deionized or distilled water to prepare 600 mL of Wash Solution (1x).
    5. TMB substrate - Aspirate the needed dosage of the solution with sterilized tips and do not dump the residual solution into the vial again.

    Note:

    1. Making serial dilution in the wells directly is not permitted.
    2. Prepare standards within 15 minutes before assay. Please do not dissolve the reagents at 37 °C directly.
    3. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals are completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10μL for one pipetting.
    4. The reconstituted Standards, Detection Reagent A and Detection Reagent B can be used only once.
    5. If crystals have formed in the Wash Solution concentrate (30x), warm to room temperature and mix gently until the crystals are completely dissolved.
    6. Contaminated water or container for reagent preparation will influence the detection result.
    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tubulin Beta (TUBb) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tubulin Beta (TUBb) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions
    For Research Use only
  • Précaution d'utilisation
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    Conseil sur la manipulation
    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
    Stock
    4 °C
    Stockage commentaire
    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.
    Date de péremption
    6 months
  • Maklad, AbdelHafez, Abdelhamid, Aly: "Tubulin inhibitors: Discovery of a new scaffold targeting extra-binding residues within the colchicine site through anchoring substituents properly adapted to their pocket by a semi-flexible linker." dans: Bioorganic chemistry, Vol. 99, pp. 103767, (2020) (PubMed).

    Mustafa, Anwar, Elgamal, Ahmed, Aly: "Potent combretastatin A-4 analogs containing 1,2,4-triazole: Synthesis, antiproliferative, anti-tubulin activity, and docking study." dans: European journal of medicinal chemistry, Vol. 183, pp. 111697, (2019) (PubMed).

    El-Bakhshawangy, El-Nassan, Kassab, Taher: "Design, synthesis and biological evaluation of chromenopyrimidines as potential cytotoxic agents." dans: Future medicinal chemistry, Vol. 10, Issue 12, pp. 1465-1481, (2019) (PubMed).

  • Antigène Voir toutes TUBB Kits ELISA
    TUBB (Tubulin, beta (TUBB))
    Autre désignation
    Tubulin Beta (TUBB Produits)
    Synonymes
    M40 Kit ELISA, OK/SW-cl.56 Kit ELISA, TUBB1 Kit ELISA, TUBB5 Kit ELISA, XLOT Kit ELISA, m40 Kit ELISA, ok/sw-cl.56 Kit ELISA, tubb1 Kit ELISA, tubb5 Kit ELISA, TUBB2A Kit ELISA, TUBB2B Kit ELISA, TUBB Kit ELISA, 1t Kit ELISA, B1t Kit ELISA, BETA 56D Kit ELISA, CG9277 Kit ELISA, DTB2 Kit ELISA, Dmbeta1 Kit ELISA, Dmel\\CG9277 Kit ELISA, T Kit ELISA, Tub Kit ELISA, Tubulin Kit ELISA, beta Kit ELISA, beta-Tub Kit ELISA, beta-Tub56D Kit ELISA, beta-tub Kit ELISA, beta-tubulin56D Kit ELISA, beta1 Kit ELISA, beta1-Tubulin Kit ELISA, beta1-tub Kit ELISA, beta1Tub Kit ELISA, beta1t Kit ELISA, beta1tub Kit ELISA, beta56D Kit ELISA, betaTub Kit ELISA, betaTub1 Kit ELISA, beta[[1]] tubulin Kit ELISA, beta[[1]]-tubulin Kit ELISA, betatub(56D) Kit ELISA, 143391_i_at Kit ELISA, 3t Kit ELISA, B3t Kit ELISA, BETA 60D Kit ELISA, CG3401 Kit ELISA, D.m.BETA-60D Kit ELISA, DTB3 Kit ELISA, Dmbeta3 Kit ELISA, Dmel\\CG3401 Kit ELISA, Tub60D Kit ELISA, beta-Tub60D Kit ELISA, beta-Tub6D Kit ELISA, beta3 Kit ELISA, beta3 TU Kit ELISA, beta3-Tub Kit ELISA, beta3-tubulin Kit ELISA, beta3TUB Kit ELISA, beta3Tub Kit ELISA, beta3t Kit ELISA, beta60C Kit ELISA, betaTub3 Kit ELISA, betaTub60C Kit ELISA, beta[[3]] tubulin Kit ELISA, beta[[3]]-Tub Kit ELISA, beta[[3]]-tubulin Kit ELISA, betatub60D Kit ELISA, p50 Kit ELISA, p50/tubulin Kit ELISA, p53 Kit ELISA, p53/tubulin Kit ELISA, 2t Kit ELISA, B2t Kit ELISA, BETA 85D Kit ELISA, BETA2 Kit ELISA, CG9359 Kit ELISA, D.m.BETA-85D Kit ELISA, DTB4 Kit ELISA, Dmbeta2 Kit ELISA, Dmel\\CG9359 Kit ELISA, beta(2)Tu Kit ELISA, beta(2)Tub Kit ELISA, beta-Tub85D Kit ELISA, beta-tub85D Kit ELISA, beta2 Kit ELISA, beta2-tub Kit ELISA, beta2t Kit ELISA, beta2tub Kit ELISA, beta85D Kit ELISA, betaTub2 Kit ELISA, beta[[2]]-tubulin Kit ELISA, ms(3)KK[D] Kit ELISA, 4t Kit ELISA, B4t Kit ELISA, BETA 98B Kit ELISA, CG4869 Kit ELISA, DTB1 Kit ELISA, Dmbeta4 Kit ELISA, Dmel\\CG4869 Kit ELISA, beta-Tub97EF Kit ELISA, beta4 Kit ELISA, beta4t Kit ELISA, beta97F Kit ELISA, betaTub4 Kit ELISA, betaTub98BC Kit ELISA, betaTub98C Kit ELISA, Tub1 Kit ELISA, bmtub1 Kit ELISA, Tub3 Kit ELISA, bmtub3 Kit ELISA, Tub2 Kit ELISA, bmtub2 Kit ELISA, Tub4 Kit ELISA, bmtub4 Kit ELISA, LOC100101153 Kit ELISA, tubulin beta class I Kit ELISA, putative cobalt-zinc-cadmium outer membrane resistance protein Kit ELISA, Tubulin beta chain Kit ELISA, tubulin beta-2A chain Kit ELISA, beta-Tubulin at 56D Kit ELISA, beta-Tubulin at 60D Kit ELISA, beta-Tubulin at 85D Kit ELISA, beta-Tubulin at 97EF Kit ELISA, beta-tubulin Kit ELISA, tubulin beta 6 class V Kit ELISA, beta tubulin Kit ELISA, tubulin beta class I L homeolog Kit ELISA, tubulin, beta 5 class I Kit ELISA, TUBB Kit ELISA, czcC Kit ELISA, tbb-6 Kit ELISA, tubb Kit ELISA, LOC462399 Kit ELISA, betaTub56D Kit ELISA, betaTub60D Kit ELISA, betaTub85D Kit ELISA, betaTub97EF Kit ELISA, Tub1 Kit ELISA, Tub3 Kit ELISA, Tub2 Kit ELISA, Tub4 Kit ELISA, TVAG_525430 Kit ELISA, TVAG_062880 Kit ELISA, TVAG_456920 Kit ELISA, LOC100101153 Kit ELISA, TUBB6 Kit ELISA, Tb927.1.2330 Kit ELISA, Tb927.1.2350 Kit ELISA, Tb927.1.2370 Kit ELISA, Tb927.1.2390 Kit ELISA, tubb.L Kit ELISA, Tubb Kit ELISA, LOC693049 Kit ELISA, LOC443015 Kit ELISA, Tubb5 Kit ELISA
    Pathways
    Dynamique des Microtubules, M Phase
Vous êtes ici:
Support technique