Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Bevacizumab Specific Kit ELISA

Kit ELISA Bevacizumab Specific Humain, Singe, Souris et Rat, Colorimetric test pour la quantification de Humain, Singe, Souris et Rat Bevacizumab Specific.
N° du produit ABIN5012826
653,58 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 6 à 8 jours ouvrables

Aperçu rapide pour Bevacizumab Specific Kit ELISA (ABIN5012826)

Antigène

Bevacizumab Specific

Reactivité

Humain, Singe, Souris, Rat

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Application

ELISA

Type d'échantillon

Plasma, Serum
  • Fonction

    Enzyme immunoassay for the specific quantitative determination of free Bevacizumab in serum and plasma

    Analytical Method

    Quantitative

    Specificité

    There is no cross reaction with any other proteins present in native human serum. A screening test was performed with 48 different native human sera. All produced OD450/620 nm values (ranged from 0.022 to 0.042) less than the mean OD (0.132) of standard D (6 ng/mL). In addition, binding of Bevacizumab is inhibited by recombinant human VEGF-A in a concentration dependent manner. Therefore, the Bevacizumab ELISA (mAb-Based) measures the biologically active free form of Bevacizumab, i.e. not pre-occupied by VEGF. No cross reaction was observed with sera spiked with the other therapeutic antibodies including Infliximab, Adalimumab, Etanercept, Rituximab, Tocilizumab, Trastuzumab, Aflibercept and Golimumab at concentrations up to 2 mg/mL. All produced mean OD450/620 nm values ranged from 0.009 to 0.022. In addition, there is no cross reaction with Ranibizumab as well. Because when anti-human kappa monoclonal antibody was used as the conjugate instead, Ranibizumab did not bind to MAY-2B5 mAb-coated plate.

    Ingrédients

    plate, standards, assay buffer, conjugate, TMB, HCl, wash buffer

    Matériel non inclus

    normal lab equipment for performing ELISA assays
  • Volume d'échantillon

    20 μL

    Durée du test

    1.5 h

    Plaque

    Pre-coated

    Protocole

    This ELISA is based on Bevacizumab-specific mouse monoclonal antibody (catcher Ab, clone MAY-2B5). Standards and diluted samples are incubated in the microtiter plate coated with IG-MAY-2B5 mAb. After incubation, the wells are washed. A horseradish peroxidase (HRP)-conjugated anti-human IgG monoclonal antibody is added and binds to the Fc part of Bevacizumab. Following incubation, wells are washed and the bound enzymatic activity is detected by addition of chromogen-substrate. The color developed is proportional to the amount of Bevacizumab in the sample or standard. Results of samples can be determined by using the standard curve. Binding of Bevacizumab to the solid phase, pre-coated with MAY-2B5, is inhibited by human VEGF-A in a concentration dependent manner. Therefore, the Bevacizumab ELISA (mAb-Based) measures the free form of Bevacizumab.

    Préparation des réactifs

    Just the wash buffer has to be prepared by diluting the stock solution 1:20. All other reagents are ready to use.

    Prélèvement de l'échantillon

    normal serum or plasma collection

    Préparation de l'échantillon

    dilute the samples 1:20 with assay buffer

    Calcul des résultats

    The results are read from a standard curve.

    Précision du teste

    < 10%

    Restrictions

    For Research Use only
  • Agent conservateur

    Sodium azide

    Stock

    4 °C

    Date de péremption

    24 months
  • Antigène

    Bevacizumab Specific

    Sujet

    The drug Bevacizumab (trade name Avastin®) is a recombinant human IgG1: monoclonal antibody specific for all human vascular endothelial growth factor-A (VEGF-A) isoforms and it has been approved by the FDA as a first-line treatment for metastatic colorectal cancer in combination with chemotherapy. Furthermore, VEGF is implicated in intraocular neovascularization associated with diabetic retinopathy and age-related macular degeneration. According to the data indicated in the prescribing information and the literature, serum/plasma Bevacizumab concentration of patients, under the treatment of Bevacizumab as an intravenous (IV) infusion at various doses of 5-15 mg/kg every 2-3 weeks, reported to be ranging from 10 μg/mL as the Cmin to 200 μg/mL as the Cmax. Serum through levels might be related to predict some clinical outcome during maintenance therapy. It was also possible that the surveillance of circulating concentration during maintenance therapy represents a direct and/or indirect factor for some other side effects. In this context, identification of biomarkers for (non-) response and risk factors for adverse drug reactions that might be related to serum drug levels and maintaining the effective concentration in order to potentially avoid some side effects with a reliable method might be beneficial.