Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Nivolumab Specific Kit ELISA

Ce kit ELISA Colorimetric est destiné à la mesure quantitative de Humain Nivolumab Specific.
N° du produit ABIN5012827
653,58 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 6 à 8 jours ouvrables

Aperçu rapide pour Nivolumab Specific Kit ELISA (ABIN5012827)

Antigène

Nivolumab Specific

Reactivité

Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Application

ELISA

Type d'échantillon

Plasma, Serum
  • Fonction

    Enzyme immunoassay for the specific quantitative determination of free Nivolumab in serum and plasma

    Analytical Method

    Quantitative

    Specificité

    There is no cross reaction with any other proteins present in native human serum. A screening test was performed with 48 different native human sera. All produced OD450/620 nm values (ranged from 0.043 to 0.100) less than the mean OD (0.150) of standard D (20 ng/mL). In addition, binding of Nivolumab to the solid phase is inhibited by recombinant human PD-1 protein in a concentration dependent manner. Therefore, the Nivolumab ELISA (mAb-Based) measures the biologically active free form of Nivolumab, i.e. not pre-occupied by human PD-1 antigen. No cross reaction was observed with sera spiked with the other therapeutic antibodies including Cetuximab, Aflibercept, Rituximab, Trastuzumab, Bevacizumab, Vedolizumab, Infliximab and Adalimumab at concentrations up to 200 μg/mL. All produced mean OD450/620 nm values (ranged from 0.024 to 0.030) less than standard D.

    Ingrédients

    plate, standards, assay buffer, conjugate, TMB, HCl, wash buffer

    Matériel non inclus

    normal lab equipment for performing ELISA assays
  • Volume d'échantillon

    20 μL

    Durée du test

    1.5 h

    Plaque

    Pre-coated

    Protocole

    This ELISA is based on Nivolumab-specific mouse monoclonal antibody (catcher Ab, clone NY-11C3). Diluted standards and samples are incubated in the microtiter plate coated with IG-NY-11C3 mAb. After incubation, the wells are washed. A horseradish peroxidase (HRP)-conjugated anti-human IgG antibody is added and binds to the Fc part of Nivolumab. Following incubation, wells are washed and the bound enzymatic activity is detected by addition of chromogen-substrate. The color developed is proportional to the amount of Nivolumab in the sample or standard. Results of samples can be determined by using the standard curve.

    Préparation des réactifs

    Just the wash buffer has to be prepared by diluting the stock solution 1:20. All other reagents are ready to use.

    Prélèvement de l'échantillon

    normal serum or plasma collection

    Préparation de l'échantillon

    dilute the samples 1:20 with assay buffer

    Calcul des résultats

    The results are read from a standard curve.

    Précision du teste

    < 10%

    Restrictions

    For Research Use only
  • Agent conservateur

    Sodium azide

    Stock

    4 °C

    Date de péremption

    24 months
  • Antigène

    Nivolumab Specific

    Sujet

    The drug Nivolumab (Opdivo®) is a fully human IgG4 monoclonal antibody that binds specifically to programmed death-1 (PD-1), a negative regulatory receptor expressed by activated T and B lymphocytes. Binding of Nivolumab to the PD-1 receptor blocks its interaction with the ligands, PDL1 and PD-L2, thereby attenuating PD-1-mediated inhibition of the immune response, including the anti-tumor immune response. According to the prescribing information, Nivolumab at 3 mg/kg every 2 weeks has been shown to be safe and efficacious in the treatment of advanced melanoma, refractory non-small cell lung cancer (NSCLC), and advanced renal cell carcinoma, and it is being studied in patients with other solid tumors and hematologic malignancies. Following the recommended dose regimen (3 mg/kg every 2 week), the mean Cmin (trough) and Cmax concentrations of Nivolumab were reported to be 15 μg/mL and 68.8 μg/mL, respectively. Identification of biomarkers for (non-) response and risk factors for adverse drug reactions that might be related to serum drug levels and maintaining the effective concentration in order to potentially avoid some side effects with a reliable method might be beneficial.
Vous êtes ici:
Chat with us!