Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

GNRH1 Kit ELISA

GNRH1 Reactivité: Poulet Colorimetric Competition ELISA 31.25 pg/mL - 2000 pg/mL Plasma, Serum, Tissue Homogenate
N° du produit ABIN5520316
  • Antigène Voir toutes GNRH1 Kits ELISA
    GNRH1 (Gonadotropin-Releasing Hormone 1 (Luteinizing-Releasing Hormone) (GNRH1))
    Reactivité
    • 7
    • 6
    • 6
    • 5
    • 4
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    Poulet
    Méthode de détection
    Colorimetric
    Type de méthode
    Competition ELISA
    Gamme de detection
    31.25 pg/mL - 2000 pg/mL
    Seuil minimal de détection
    31.25 pg/mL
    Application
    ELISA
    Fonction
    For quantitative detection of LHRH/GnRH in serum, plasma, tissue homogenates.
    Type d'échantillon
    Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of LHRH/GnRH. No significant cross- reactivity or interference between LHRH/GnRH and analogues was observed. Note: Limited by current skills and knowledge, it is difficult for us to complete the cross-reactivity detection between LHRH/GnRH and all the analogues, therefore, cross reaction may still exist.
    Sensibilité
    18.75 pg/mL
    Ingrédients
    • Pre-coated, ready to use 96-well strip plate
    • Plate sealer for 96 wells
    • Standard
    • Standard Dilution Buffer
    • Biotin-labeled Antibody (Concentrated)
    • Antibody Dilution Buffer
    • HRP-Streptavidin Conjugate (SABC)
    • SABC Dilution Buffer
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (25 x concentrate)
    • Instruction manual
    Featured
    Discover our best selling GNRH1 Kit ELISA
    Top Product
    Discover our top product GNRH1 Kit ELISA
  • Indications d'application
    Optimal working dilution should be determined by the investigator.
    Volume d'échantillon
    50 μL
    Plaque
    Pre-coated
    Protocole
    1. Wash plate 2 times before adding Standard, Sample and Control (blank) wells!
    2. Add 50 µL Standard or Sample into each well. Immediately add 50 µL Biotin-labeled Antibody into each well, gently tap the plate to ensure thorough mixing then incubate for 45 minutes at 37 °C.
    3. Aspirate and wash plates 3 times.
    4. Add 100 µL SABC Working Solution into each well and incubate for 30 minutes at 37 °C.
    5. Aspirate and wash plates 5 times.
    6. Add 90 µL TMB Substrate Solution. Incubate 10-20 minutes at 37 °C.
    7. Add 50 µL Stop Solution. Read at 450nm immediately and calculation.
    Préparation des réactifs
    • Bring all reagents and samples to room temperature for 20 minutes before use.
    • Wash Buffer: If crystals have formed in the concentrate, you can warm it with 40 °C water bath Concentrated Wash Buffer into 750 mL Wash Buffer with deionized or distilled water. Put unused solution back at 2-8 °C.
    • Standards:
      1. Add 1 mL Sample Dilution Buffer into one Standard tube (labeled as zero tube), keep the tube at room temperature for 10 minutes and mix them thoroughly. Note: If the standard tube concentration higher than the range of the kit,please dilute it and labeled as zero tube.
      2. Label 7 EP tubes with 1/2, 1/4, 1/8, 1/16, 1/32, 1/64 and blank respectively. Add 0.3 mLof the Sample Dilution Buffer into each tube. Add 0.3 mLof the above Standard solution (from zero tube) into 1st tube and mix them thoroughly. Transfer 0.3 mL from 1st tube to 2nd tube and mix them thoroughly. Transfer 0.3 mL from 2nd tube to 3rd tube and mix them thoroughly, and so on. Sample Dilution Buffer was used for the blank control. Note: It is best to use Standard Solutions within 2 hours.
    • Preparation of Biotin-labeled Antibody Working Solution:
      Prepare it within 1 hour before experiment.
      1. Calculate required total volume of the working solution: 0.05ml/well x quantity of wells. (Allow 0.1-0.2 mLmore than the total volume.)
      2. Dilute the Biotin-detection antibody with Antibody Dilution Buffer at 1:100 and mix them thoroughly. (i.e. Add 1 µL Biotin-labeled antibody into 99 µL Antibody Dilution Buffer.)
    • Preparation of HRP-Streptavidin Conjugate (SABC) Working Solution:
      Prepare it within 30 minutes before experiment.
      1. Calculate required total volume of the working solution: 0.1ml/well x quantity of wells. (Allow 0.1-0.2 mLmore than the total volume.)
      2. Dilute the SABC with SABC Dilution Buffer at 1:100 and mix them thoroughly. (i.e. Add 1 µL of SABC into 99 µL of SABC Dilution Buffer.)
    Restrictions
    For Research Use only
  • Stock
    4 °C
    Stockage commentaire
    1. For unopened kit: All the reagents should be kept according to the labels on vials. The Reference Standard and the 96-well stripe plate should be stored at -20 °C upon receipt while the other reagents should be stored at 4 °C.
    2. For used kit: When the kit is used, the remaining reagents need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and zip-seal the foil pouch.
    Date de péremption
    6 months
  • Antigène Voir toutes GNRH1 Kits ELISA
    GNRH1 (Gonadotropin-Releasing Hormone 1 (Luteinizing-Releasing Hormone) (GNRH1))
    Autre désignation
    LHRH/GnRH (GNRH1 Produits)
    Synonymes
    GNRH Kit ELISA, GRH Kit ELISA, HH12 Kit ELISA, LHRH Kit ELISA, LNRH Kit ELISA, Gnrh Kit ELISA, Gnrh2 Kit ELISA, Lhrh1 Kit ELISA, Lnrh Kit ELISA, hpg Kit ELISA, Gnrha Kit ELISA, Lhrh Kit ELISA, Rgnrhg1 Kit ELISA, CGNRH-I Kit ELISA, GnRH-I Kit ELISA, GnRH Kit ELISA, gnrh Kit ELISA, gnrh1 Kit ELISA, grh Kit ELISA, lhrh Kit ELISA, lnrh Kit ELISA, mdGnRH Kit ELISA, mdgnrh Kit ELISA, mfGnRH Kit ELISA, gonadotropin releasing hormone 1 Kit ELISA, gonadotropin releasing hormone 1 L homeolog Kit ELISA, prepro-gonadotropin-releasing hormone Kit ELISA, GNRH1 Kit ELISA, Gnrh1 Kit ELISA, gnrh1.L Kit ELISA, gnrh1 Kit ELISA
    UniProt
    P37042
    Pathways
    Hormone Activity
Vous êtes ici:
Support technique