Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

KISS1 Kit ELISA

KISS1 Reactivité: Humain Colorimetric Competition ELISA 24.69 pg/mL - 2000 pg/mL Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
N° du produit ABIN5564715
  • Antigène Voir toutes KISS1 Kits ELISA
    KISS1 (KiSS-1 Metastasis-Suppressor (KISS1))
    Reactivité
    • 7
    • 4
    • 4
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Competition ELISA
    Gamme de detection
    24.69 pg/mL - 2000 pg/mL
    Seuil minimal de détection
    24.69 pg/mL
    Application
    ELISA
    Type d'échantillon
    Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificité

    This assay has high sensitivity and excellent specificity for detection of Kisspeptin 1 (KISS1).
    No significant cross-reactivity or interference between Kisspeptin 1 (KISS1) and analogues was observed.

    Sensibilité
    9.27 pg/mL
    Ingrédients
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • Reagent Diluent (if Detection Reagent is lyophilized)
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30 x concentrate)
    • Instruction manual
    Featured
    Discover our best selling KISS1 Kit ELISA
    Top Product
    Discover our top product KISS1 Kit ELISA
  • Durée du test
    2 h
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards,
    2. Add 50μL standard or sample to each well.
      Then add 50μL prepared Detection Reagent A immediately.
      Shake and mix. Incubate 1 hour at 37 °C,
    3. Aspirate and wash 3 times,
    4. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37 °C,
    5. Aspirate and wash 5 times,
    6. Add 90μL Substrate Solution. Incubate 10-20 minutes at 37 °C,
    7. Add 50μL Stop Solution. Read at 450 nm immediately.
    Préparation des réactifs
    1. Bring all kit components and samples to room temperature (18-25 °C) before use. If the kit will not be used up in one time, please only take out strips and reagents for present experiment, and leave the remaining strips and reagents in required condition.
    2. Standard - Reconstitute the Standard with 1.0 mL of Standard Diluent, kept for 10 minutes at room temperature, shake gently(not to foam). The concentration of the standard in the stock solution is 6,000pg/mL. Please firstly dilute the stock solution to 2,000pg/mL and the diluted standard serves as the highest standard (2,000pg/mL). Then prepare 5 tubes containing 0.6 mL Standard Diluent and produce a triple dilution series according to the picture shown below. Mix each tube thoroughly before the next transfer. Set up 5 points of diluted standard such as 2,000pg/mL, 666.67pg/mL, 222.22pg/mL, 74.07pg/mL, 24.69pg/mL, and the last EP tubes with Standard Diluent is the blank as 0pg/mL.
    3. Detection Reagent A and Detection Reagent B - If lyophilized reconstitute the Detection Reagent A with 150μL of Reagent Diluent, kept for 10 minutes at room temperature, shake gently (not to foam). Briefly spin or centrifuge the stock Detection A and Detection B before use. Dilute them to the working concentration 100-fold with Assay Diluent A and B, respectively.
    4. Wash Solution - Dilute 20 mL of Wash Solution concentrate (30x) with 580 mL of deionized or distilled water to prepare 600 mL of Wash Solution (1x).
    5. TMB substrate - Aspirate the needed dosage of the solution with sterilized tips and do not dump the residual solution into the vial again.

    Note:

    1. Making serial dilution in the wells directly is not permitted.
    2. Prepare standard within 15 minutes before assay. Please do not dissolve the reagents at 37 °C directly.
    3. Detection Reagent A and B are sticky solutions, therefore, slowly pipette them to reduce the volume errors.
    4. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals are completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10μL for one pipetting.
    5. The reconstituted Standards, Detection Reagent A and Detection Reagent B can be used only once.
    6. If crystals have formed in the Wash Solution concentrate (30x), warm to room temperature and mix gently until the crystals are completely dissolved.
    7. Contaminated water or container for reagent preparation will influence the detection result.
    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Kisspeptin 1 (KISS1) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Kisspeptin 1 (KISS1) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions
    For Research Use only
  • Précaution d'utilisation
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    Conseil sur la manipulation
    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
    Stock
    4 °C
    Stockage commentaire
    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.
    Date de péremption
    6 months
  • Antigène Voir toutes KISS1 Kits ELISA
    KISS1 (KiSS-1 Metastasis-Suppressor (KISS1))
    Autre désignation
    Kisspeptin 1 (KISS1) (KISS1 Produits)
    Synonymes
    HH13 Kit ELISA, KiSS-1 Kit ELISA, metastatin Kit ELISA, Eseptin Kit ELISA, KiSS-1 metastasis-suppressor Kit ELISA, KISS1 Kit ELISA, kiss1 Kit ELISA, Kiss1 Kit ELISA
    UniProt
    Q15726
    Pathways
    Positive Regulation of Peptide Hormone Secretion
Vous êtes ici:
Support technique