Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Angiotensin 1-9 Kit ELISA

Kit ELISA Humain Angiotensin 1-9, test Colorimetric pour la quantification de Humain Angiotensin 1-9.
N° du produit ABIN5651771

Aperçu rapide pour Angiotensin 1-9 Kit ELISA (ABIN5651771)

Antigène

Tous les produits Angiotensin 1-9 (Ang1-9)
Angiotensin 1-9 (Ang1-9)

Reactivité

  • 2
  • 1
  • 1
Humain

Méthode de détection

Colorimetric

Type de méthode

Competition ELISA

Gamme de detection

2.47 pg/mL - 200 pg/mL

Application

ELISA

Type d'échantillon

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Seuil minimal de détection

    2.47 pg/mL

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Angiotensin 1-9 (Ang1-9). No significant cross-reactivity or interference between Angiotensin 1-9 (Ang1-9) and analogues was observed.

    Sensibilité

    0.97 pg/mL
  • Commentaires

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Durée du test

    2 h

    Plaque

    Pre-coated

    Protocole

    This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Angiotensin 1-9 (Ang1-9) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Angiotensin 1-9 (Ang1-9) and unlabeled Angiotensin 1-9 (Ang1-9) (Standards or samples) with the pre-coated antibody specific to Angiotensin 1-9 (Ang1-9). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Angiotensin 1-9 (Ang1-9) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Angiotensin 1-9 (Ang1-9) in the sample.

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin 1-9 (Ang1-9) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin 1-9 (Ang1-9) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    4-8 months
  • Antigène Tous les produits Angiotensin 1-9 (Ang1-9)

    Angiotensin 1-9 (Ang1-9)

    Autre désignation

    Angiotensin 1-9

    Sujet

    Gene Name: Angiotensin 1-9

Vous êtes ici:
Chat with us!