Aprotinin Kit CLIA

Ce kit ELISA Chemiluminescent est destiné à la mesure quantitative de Boeuf (Vache) Aprotinin.
N° du produit ABIN5651970
1.479,92 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 12 à 18 jours ouvrables

Aperçu rapide pour Aprotinin Kit CLIA (ABIN5651970)

Antigène

Voir toutes Aprotinin Kits CLIA
Aprotinin

Reactivité

  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Boeuf (Vache)

Méthode de détection

Chemiluminescent

Type de méthode

Competition ELISA

Gamme de detection

1.95 ng/mL - 500 ng/mL

Application

ELISA

Type d'échantillon

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Seuil minimal de détection

    1.95 ng/mL

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Aprotinin (AP). No significant cross-reactivity or interference between Aprotinin (AP) and analogues was observed.

    Sensibilité

    0.71 ng/mL
  • Commentaires

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Durée du test

    2 h

    Plaque

    Pre-coated

    Protocole

    The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Aprotinin (AP). A competitive inhibition reaction is launched between biotin labeled Aprotinin (AP) and unlabeled Aprotinin (AP) (Standards or samples) with the pre-coated antibody specific to Aprotinin (AP). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Aprotinin (AP) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Aprotinin (AP) level in the sample or standard.

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Aprotinin (AP) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Aprotinin (AP) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    4-8 months
  • Antigène Voir toutes Aprotinin Kits CLIA

    Aprotinin

    Autre désignation

    Aprotinin

    Sujet

    Gene Name: Aprotinin

    Gene Aliases: BPTI, Trasylol, Pancreatic Trypsin Inhibitor, Basic protease inhibitor