XCL2 Kit CLIA

Kit ELISA Humain XCL2, test Chemiluminescent pour la quantification de Humain XCL2.
N° du produit ABIN5652842

Aperçu rapide pour XCL2 Kit CLIA (ABIN5652842)

Antigène

Voir toutes XCL2 Kits CLIA
XCL2 (Chemokine (C Motif) Ligand 2 (XCL2))

Reactivité

  • 2
  • 1
Humain

Méthode de détection

Chemiluminescent

Type de méthode

Sandwich ELISA

Gamme de detection

156.25 pg/mL - 10000 pg/mL

Application

ELISA

Type d'échantillon

Plasma, Serum
  • Seuil minimal de détection

    156.25 pg/mL

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Chemokine C-Motif Ligand 2 (XCL2). No significant cross-reactivity or interference between Chemokine C-Motif Ligand 2 (XCL2) and analogues was observed.

    Sensibilité

    5 pg/mL
  • Commentaires

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Durée du test

    2 - 3 h

    Plaque

    Pre-coated

    Protocole

    The microplate provided in this kit has been pre-coated with an antibody specific to Chemokine C-Motif Ligand 2 (XCL2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Chemokine C-Motif Ligand 2 (XCL2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Chemokine C-Motif Ligand 2 (XCL2) level in the sample or standard.,

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine C-Motif Ligand 2 (XCL2) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine C-Motif Ligand 2 (XCL2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    4-8 months
  • Antigène Voir toutes XCL2 Kits CLIA

    XCL2 (Chemokine (C Motif) Ligand 2 (XCL2))

    Autre désignation

    Chemokine C-Motif Ligand 2

    Sujet

    Gene Name: Chemokine C-Motif Ligand 2

    Gene Aliases: SCYC2, SCM-1b, Small Inducible Cytokine Subfamily C Member 2, Cytokine SCM-1 beta, C motif chemokine 2, XC chemokine ligand 2