OxLDL Kit CLIA

Ce kit ELISA Chemiluminescent est destiné à la mesure quantitative de Souris OxLDL.
N° du produit ABIN5657574
1.291,85 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 12 à 18 jours ouvrables

Aperçu rapide pour OxLDL Kit CLIA (ABIN5657574)

Antigène

Voir toutes OxLDL Kits CLIA
OxLDL (Oxidized Low Density Lipoprotein (OxLDL))

Reactivité

  • 15
  • 13
  • 9
  • 4
  • 1
  • 1
Souris

Méthode de détection

Chemiluminescent

Type de méthode

Sandwich ELISA

Gamme de detection

1.37 pg/mL - 1000 pg/mL

Application

ELISA

Type d'échantillon

Plasma, Serum
  • Seuil minimal de détection

    1.37 pg/mL

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Oxidized Low Density Lipoprotein (OxLDL). No significant cross-reactivity or interference between Oxidized Low Density Lipoprotein (OxLDL) and analogues was observed.

    Sensibilité

    0.56 pg/mL
  • Commentaires

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Durée du test

    2 - 3 h

    Plaque

    Pre-coated

    Protocole

    The microplate provided in this kit has been pre-coated with an antibody specific to Oxidized Low Density Lipoprotein (OxLDL). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Oxidized Low Density Lipoprotein (OxLDL). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Oxidized Low Density Lipoprotein (OxLDL) level in the sample or standard.,

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    4-8 months
  • Antigène Voir toutes OxLDL Kits CLIA

    OxLDL (Oxidized Low Density Lipoprotein (OxLDL))

    Autre désignation

    Oxidized Low Density Lipoprotein

    Sujet

    Gene Name: Oxidized Low Density Lipoprotein

    Gene Aliases: OL