Testosterone Kit CLIA

Le kit ELISA Testosterone (ABIN5659132) Différentes espèces est un kit ELISA Chemiluminescent conçu pour quantifier Différentes espèces Testosterone.
N° du produit ABIN5659132
1.229,54 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 12 à 18 jours ouvrables

Aperçu rapide pour Testosterone Kit CLIA (ABIN5659132)

Antigène

Voir toutes Testosterone Kits CLIA
Testosterone

Reactivité

  • 20
  • 15
  • 9
  • 9
  • 6
  • 6
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
Différentes espèces

Méthode de détection

Chemiluminescent

Type de méthode

Competition ELISA

Gamme de detection

117.2 pg/mL - 30000 pg/mL

Application

ELISA

Type d'échantillon

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • Seuil minimal de détection

    117.2 pg/mL

    Fonction

    Testosterone (Testo) CLIA Kit for detecting Testo in serum, plasma, tissue homogenates, cell lysates, cell culture supernates

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Testosterone (Testo). No significant cross-reactivity or interference between Testosterone (Testo) and analogues was observed.

    Sensibilité

    40.5 pg/mL

    Ingrédients

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • Substrate A
    • Substrate B
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Matériel non inclus

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Indications d'application

    Optimal working dilution should be determined by the investigator.

    Commentaires

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Volume d'échantillon

    50 μL

    Durée du test

    2 h

    Plaque

    Pre-coated

    Protocole

    The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Testosterone (Testo). A competitive inhibition reaction is launched between biotin labeled Testosterone (Testo) and unlabeled Testosterone (Testo) (Standards or samples) with the pre-coated antibody specific to Testosterone (Testo). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Testosterone (Testo) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Testosterone (Testo) level in the sample or standard.

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Testosterone (Testo) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Testosterone (Testo) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    12 months
  • Antigène Voir toutes Testosterone Kits CLIA

    Testosterone

    Classe de substances

    Hormone

    Sujet

    Gene Aliases: T, Testesteron, Testeronun