Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Cardiac Troponin T2 Kit CLIA

Ce kit ELISA Chemiluminescent est destiné à la mesure quantitative de Rat Cardiac Troponin T2.
N° du produit ABIN5659575
1.355,31 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 12 à 18 jours ouvrables

Aperçu rapide pour Cardiac Troponin T2 Kit CLIA (ABIN5659575)

Antigène

Voir toutes Cardiac Troponin T2 (cTnT) Kits CLIA
Cardiac Troponin T2 (cTnT) (Cardiac Troponin T (cTnT))

Reactivité

  • 10
  • 9
  • 7
  • 5
  • 4
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
Rat

Méthode de détection

Chemiluminescent

Type de méthode

Sandwich ELISA

Gamme de detection

46.88 pg/mL - 3000 pg/mL

Application

ELISA

Type d'échantillon

Plasma, Serum
  • Seuil minimal de détection

    46.88 pg/mL

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Troponin T Type 2, Cardiac (TNNT2). No significant cross-reactivity or interference between Troponin T Type 2, Cardiac (TNNT2) and analogues was observed.

    Sensibilité

    1.78 pg/mL
  • Commentaires

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Durée du test

    2 - 3 h

    Plaque

    Pre-coated

    Protocole

    The microplate provided in this kit has been pre-coated with an antibody specific to Troponin T Type 2, Cardiac (TNNT2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Troponin T Type 2, Cardiac (TNNT2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Troponin T Type 2, Cardiac (TNNT2) level in the sample or standard.,

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Troponin T Type 2, Cardiac (TNNT2) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Troponin T Type 2, Cardiac (TNNT2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    4-8 months
  • Antigène Voir toutes Cardiac Troponin T2 (cTnT) Kits CLIA

    Cardiac Troponin T2 (cTnT) (Cardiac Troponin T (cTnT))

    Autre désignation

    Troponin T Type 2, Cardiac

    Sujet

    Gene Name: Troponin T Type 2, Cardiac

    Gene Aliases: CMH2, cTnT, TnTc, Cardiomyopathy,Hypertrophic 2, Cardiac muscle troponin T

    ID gène

    24837

    UniProt

    P50753
Vous êtes ici:
Chat with us!