Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

UACA Kit ELISA

Kit ELISA UACA Humain, Colorimetric test pour la quantification de Humain UACA.
N° du produit ABIN5659799
1.168,38 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 12 à 18 jours ouvrables

Aperçu rapide pour UACA Kit ELISA (ABIN5659799)

Antigène

Voir toutes UACA Kits ELISA
UACA (Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA))

Reactivité

  • 7
  • 5
  • 1
  • 1
Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Gamme de detection

0.312 ng/mL - 20 ng/mL

Application

ELISA

Type d'échantillon

Tissue Homogenate
  • Seuil minimal de détection

    0.312 ng/mL

    Fonction

    Human Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA) ELISA Kit for detecting UACA in tissue homogenates

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA). No significant cross-reactivity or interference between Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA) and analogues was observed.

    Sensibilité

    0.108 ng/mL

    Ingrédients

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • TMB Substrate
    • Stop Solution
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Matériel non inclus

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Indications d'application

    Optimal working dilution should be determined by the investigator.

    Commentaires

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Volume d'échantillon

    100 μL

    Durée du test

    3 h

    Plaque

    Pre-coated

    Protocole

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    12 months
  • Antigène Voir toutes UACA Kits ELISA

    UACA (Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats (UACA))

    Autre désignation

    Uveal Autoantigen With Coiled Coil Domains And Ankyrin Repeats

    Sujet

    Gene Aliases: NUCLING

    ID gène

    55075

    UniProt

    Q9BZF9

    Pathways

    Positive Regulation of Endopeptidase Activity
Vous êtes ici:
Chat with us!