Vitamin D Receptor Kit ELISA

Le kit ELISA Vitamin D Receptor (ABIN5659960) Souris est un kit ELISA Colorimetric conçu pour quantifier Souris Vitamin D Receptor.
N° du produit ABIN5659960
1.008,92 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 12 à 18 jours ouvrables

Aperçu rapide pour Vitamin D Receptor Kit ELISA (ABIN5659960)

Antigène

Voir toutes Vitamin D Receptor (VDR) Kits ELISA
Vitamin D Receptor (VDR)

Reactivité

  • 10
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Souris

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Gamme de detection

0.312 ng/mL - 20 ng/mL

Application

ELISA

Type d'échantillon

Cell Lysate, Tissue Homogenate
  • Seuil minimal de détection

    0.312 ng/mL

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Vitamin D Receptor (VDR). No significant cross-reactivity or interference between Vitamin D Receptor (VDR) and analogues was observed.

    Sensibilité

    0.113 ng/mL
  • Commentaires

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Durée du test

    3 h

    Plaque

    Pre-coated

    Protocole

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Vitamin D Receptor (VDR). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Vitamin D Receptor (VDR). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Vitamin D Receptor (VDR), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Vitamin D Receptor (VDR) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vitamin D Receptor (VDR) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vitamin D Receptor (VDR) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    4-8 months
  • Antigène Voir toutes Vitamin D Receptor (VDR) Kits ELISA

    Vitamin D Receptor (VDR)

    Autre désignation

    Vitamin D Receptor

    Classe de substances

    Chemical

    Sujet

    Gene Name: Vitamin D Receptor

    Gene Aliases: NR1I1, Nuclear Receptor Subfamily 1 Group I Member 1, Calcitriol Receptor, 1,25-dihydroxyvitamin D3 receptor

    ID gène

    22337

    UniProt

    P48281

    Pathways

    Nuclear Receptor Transcription Pathway, Steroid Hormone Mediated Signaling Pathway
Vous êtes ici:
Chat with us!