Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

WWP2 Kit ELISA

Kit ELISA WWP2 Humain, Colorimetric test pour la quantification de Humain WWP2.
N° du produit ABIN5660045
1.168,38 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 12 à 18 jours ouvrables

Aperçu rapide pour WWP2 Kit ELISA (ABIN5660045)

Antigène

Voir toutes WWP2 Kits ELISA
WWP2 (WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2))

Reactivité

  • 7
  • 2
Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Gamme de detection

0.781 ng/mL - 50 ng/mL

Application

ELISA

Type d'échantillon

Cell Lysate, Tissue Homogenate
  • Seuil minimal de détection

    0.781 ng/mL

    Fonction

    Human WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2) ELISA Kit for detecting WWP2 in tissue homogenates, cell lysates

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2). No significant cross-reactivity or interference between WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2) and analogues was observed.

    Sensibilité

    0.27 ng/mL

    Ingrédients

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • TMB Substrate
    • Stop Solution
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Matériel non inclus

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Indications d'application

    Optimal working dilution should be determined by the investigator.

    Commentaires

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Volume d'échantillon

    100 μL

    Durée du test

    3 h

    Plaque

    Pre-coated

    Protocole

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    12 months
  • Antigène Voir toutes WWP2 Kits ELISA

    WWP2 (WW Domain Containing E3 Ubiquitin Protein Ligase 2 (WWP2))

    Autre désignation

    WW Domain Containing E3 Ubiquitin Protein Ligase 2

    Sujet

    Gene Aliases: AIP2, WWp2-like, Atrophin-1-interacting protein 2, NEDD4-like E3 ubiquitin-protein ligase WWP2

    ID gène

    11060

    UniProt

    O00308

    Pathways

    Negative Regulation of Transporter Activity
Vous êtes ici:
Chat with us!