Anti Survivin Antibody (Anti Surv) Kit ELISA
Aperçu rapide pour Anti Survivin Antibody (Anti Surv) Kit ELISA (ABIN5696300)
Antigène
Reactivité
Méthode de détection
Type de méthode
Gamme de detection
Application
Type d'échantillon
-
-
Seuil minimal de détection
- 3.125 ng/mL
-
Fonction
- Human Anti-Surv (Anti-Survivin Antibody) ELISA Kit
-
Analytical Method
- Quantitative
-
Specificité
- Specifically binds with Surv-Ab , no obvious cross reaction with other analogues.
-
Sensibilité
- 1.875 ng/mL
-
Ingrédients
-
- ELISA Microplate(Dismountable)
- Lyophilized Standard
- Biotin-labeled Antigen(Concentrated
- 100X)
- HRP-Streptavidin Conjugate(SABC
- 100X)
- TMB Substrate
- Sample Dilution Buffer
- Stop Solution
- Plate Sealer
- Product Description
-
Matériel non inclus
-
- Microplate reader (wavelength: 450nm)
- 37 °C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5 mL pipettor
- Precision single (0.5-10μL
- 5-50μL
- 20-200μL
- 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
-
-
-
-
Indications d'application
- Optimal working dilution should be determined by the investigator.
-
Commentaires
-
Sandwich ELISA, Double Antigen
-
Volume d'échantillon
- 100 μL
-
Durée du test
- 4 h
-
Plaque
- Pre-coated
-
Protocole
- Step 1: Add 100 µL standard or sample into each well, seal the plate and statically incubate for 90 minutes at 37 °C. Washing: Wash the plate twice without immersing. Step 2: Add 100 µL biotin-antigen working solution, seal the plate and statically incubate for 60 minutes at 37 °C. Washing: Wash the plate three times and immerse for 1 min each time. Step 3: Add 100 µL HRP-Streptavidin Conjugate (SABC) working solution, seal the plate and statically incubate for 30 minutes at 37 °C. Washing: Wash the plate five times and immerse for 1 min each time. Step 4: Add 90 µL TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37 °C. (Accurate TMB visualization control is required.) Step 5: Add 50 µL stop solution. Read at 450nm immediately and calculate.
-
Restrictions
- For Research Use only
-
-
-
Conseil sur la manipulation
- Avoid direct light exposure to antibody solutions
-
Stock
- 4 °C
-
Stockage commentaire
- Store sealed Kit at 2-8° C. Do Not Cryopreserve. Store ELISA Microplate for 1 month at 2-8°C, Store for 12 month at -20°C. Put the leftover strips into a sealed foil bag with the desiccant
-
Date de péremption
- 12 months
-
-
- Anti Survivin Antibody (Anti Surv)
-
Autre désignation
- Anti-Surv (Anti-Survivin Antibody)
-
Classe de substances
- Antibody
-
Sujet
- Surv antibody, Survivin antibody
Antigène
-