Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

FTH1 Kit ELISA

FTH1 Reactivité: Rat Colorimetric Sandwich ELISA 6.25-400 ng/mL Plasma, Serum
N° du produit ABIN579138
  • Antigène Voir toutes FTH1 Kits ELISA
    FTH1 (Ferritin, Heavy Polypeptide 1 (FTH1))
    Reactivité
    • 5
    • 3
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    Rat
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    6.25-400 ng/mL
    Seuil minimal de détection
    6.25 ng/mL
    Application
    ELISA
    Fonction
    This immunoassay kit allows for the specific measurement of Rat Ferritin concentrations in serum and plasma.
    Type d'échantillon
    Serum, Plasma
    Analytical Method
    Quantitative
    Specificité
    This assay recognizes recombinant and natural Rat Ferritin.
    Réactivité croisée (Details)
    No significant cross-reactivity or interference was observed.
    Attributs du produit
    Rattus norvegicus,Rat,Ferritin heavy chain,Ferritin H subunit,Fth1,Fth,1.16.3.1
    Ingrédients
    Reagent (Quantity ): Assay plate (1), Standard 2 Sample Diluent (1 × 20ml), Assay Diluent A (1x10ml), Assay Diluent B (1x10ml), Detection Reagent A (1 × 120μl), 2 Detection Reagent B 1 x 120μl Wash Buffer (25 x concentrate) (1 × 30ml), Substrate (1 x 10ml) Stop Solution (1 x 10ml)
    Featured
    Discover our best selling FTH1 Kit ELISA
    Top Product
    Discover our top product FTH1 Kit ELISA
  • Volume d'échantillon
    100 μL
    Plaque
    Pre-coated
    Protocole
    This assay employs the quantitative sandwich enzyme immunoassay technique. A monoclonal antibody specific for Ferritin has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any Ferritin present is bound by the immobilized antibody. An enzyme-linked monoclonal antibody specific for Ferritin is added to the wells. Following a wash to remove any unbound antibody-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of Ferritin bound in the initial step. The color development is stopped and the intensity of the color is measured.
    Préparation des réactifs

    Bring all reagents to room temperature before use. Wash Buffer - If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have completely dissolved. Dilute 30 mL of Wash Buffer Concentrate into deionized or distilled water to prepare 750 mL of Wash Buffer. Standard - Reconstitute the Standard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 4,000 pg/mL. Allow the standard to sit for about 10 minutes with gentle agitation prior to making serial dilutions (Making serial dilution in the wells directly is not permitted). Please firstly dilute the stock solution to 1,000 pg/mL and the diluted standard serves as the high standard (1,000 pg/mL). The Sample Diluent serves as the zero standard (0 pg/ml). pg/mL 4,000 1,000 500 250 125 62.5 31.2 15.6 0 Detection Reagent A and B - Dilute to the working concentration using Assay Diluent A or B (1:100), respectively.

    Prélèvement de l'échantillon
    Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000 g at 2 - 8 within 30 minutes of collection. Store samples at -20 or -80 . Avoid repeated freeze-thaw cycles. Other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20 or -80 . Avoid repeated freeze-thaw cycles. Note: Plasma to be used within 7 days may be stored at 2-8, otherwise samples must stored at -20 ( 1 month) or -80 ( 2 months) to avoid loss of bioactivity and contamination. Avoid freeze-thaw cycles. When performing the assay slowly bring samples to room temperature.
    Procédure de l'essai

    Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37 directly.). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at 4 until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their particular experiments.
    1. Add 100 of Standard, Blank, or Sample per well. Cover with the Plate sealer. Incubate for two hours at 37 .
    2. Remove the liquid of each well, don’t wash.
    3. Add 100 μl of Detection Reagent A working solution to each well. Cover with the Plate sealer. Incubate for 1 hour at 37 . Detection Reagent A working solution may appear cloudy. Warm to room temperature and mix gently until solution appears uniform.
    4. Aspirate each well and wash, repeating the process three times for a total of three washes. Wash by filling each well with Wash Buffer (approximately 400 μl) using a 4 squirt bottle, multi-channel pipette, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
    5. Add 100 μl of Detection Reagent B working solution to each well. Cover with a new Plate sealer. Incubate for one hour at 37 .
    6. Repeat the aspiration/wash process for five times as conducted in step
    4. 7. Add 90 μl of Substrate Solution to each well. Cover with a new Plate sealer. Incubate for 15 - 30 minutes at 37 . Protect from light.
    8. Add 50 μl of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
    9. Determine the optical density of each well at once, using a microplate reader set to 450 nm.
    Important Note:1. Absorbance is a function of the incubation time. Therefore, prior to starting the assay it is recommended that all reagents should be freshly prepared prior to use and all required strip-wells are secured in the microtiter frame. This will ensure equal elapsed time for each pipetting step, without interruption.
    2. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. The reconstituted Standards can be used only once. This assay requires pipetting of small volumes. To minimize imprecision caused by pipetting, ensure that pipettors are calibrated. It is recommended to suck more than 10μl for once pipetting.
    3. To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Do not allow wells to sit uncovered for extended periods between incubation steps. Once reagents have been added to the well strips, DO NOT let the strips DRY at any time during the assay.
    4. For each step in the procedure, total dispensing time for addition of reagents to the assay plate should not exceed 10 minutes.
    5. To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
    6. The wash procedure is critical. Insufficient washing will result in poor precision and falsely elevated absorbance readings.
    7. Duplication of all standards and specimens, although not required, is recommended.
    8. Substrate Solution is easily contaminated. Please protect it from light.

    Calcul des résultats

    Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the TF concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. It is recommended to use some related software to do this calculation, such as curve expert 13.0. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    1. The kit should not be used beyond the expiration date on the kit label.
    2. Do not mix or substitute reagents with those from other lots or sources.
    3. If samples generate values higher than the highest standard, further dilute the samples and repeat the assay. Any variation in standard diluent, operator, pipetting technique, washing technique,incubation time or temperature, and kit age can cause variation in binding.
    4. This assay is designed to eliminate interference by soluble receptors, ligands, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
    3.
    Stock
    4 °C/-20 °C
    Stockage commentaire
    The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20 °C upon being received. The other reagents can be stored at 4 °C.
  • Antigène Voir toutes FTH1 Kits ELISA
    FTH1 (Ferritin, Heavy Polypeptide 1 (FTH1))
    Autre désignation
    Fth1 (FTH1 Produits)
    Synonymes
    FHC Kit ELISA, FTH Kit ELISA, FTHL6 Kit ELISA, PIG15 Kit ELISA, PLIF Kit ELISA, apoferritin Kit ELISA, ferritin Kit ELISA, fhc Kit ELISA, fth Kit ELISA, fth1 Kit ELISA, fthl6 Kit ELISA, ftn-2 Kit ELISA, pig15 Kit ELISA, plif Kit ELISA, fth1b Kit ELISA, Fth Kit ELISA, HFt Kit ELISA, MFH Kit ELISA, fb06g09 Kit ELISA, hm:zeh1145 Kit ELISA, wu:fb06g09 Kit ELISA, wu:fq18c10 Kit ELISA, zeh1145 Kit ELISA, ferritin heavy chain 1 Kit ELISA, ferritin, heavy polypeptide 1 L homeolog Kit ELISA, ferritin, heavy polypeptide 1 S homeolog Kit ELISA, ferritin heavy polypeptide 1 Kit ELISA, ferritin, heavy polypeptide 1a Kit ELISA, ferritin Kit ELISA, ferritin, heavy polypeptide 1 Kit ELISA, tudor domain containing 9 Kit ELISA, ferritin, heavy polypeptide 1 a Kit ELISA, FTH1 Kit ELISA, fth1.L Kit ELISA, fth1.S Kit ELISA, Fth1 Kit ELISA, fth1a Kit ELISA, EAMY_RS19690 Kit ELISA, fth1 Kit ELISA, TDRD9 Kit ELISA
    Sujet
    Ferritin is an iron-protein complex formed from an intracellular acceptor called Apoferritin. Apoferritin is a large molecular weight 450,000 protein produced by the liver. Iron as Fe (HO)3 linked to apoferritin is then stored in the cytoplasm of the reticuloendothelial system, liver, spleen and bone marrow. Ferritin is the body's iron storage protein functioning primarily as a site for iron storage from which iron may be mobilized in response to such stimuli a dietary change, blood loss or pregnancy. The direct quantitation of serum ferritin offers the physician a convenient and accurate measure of total body iron stores, by means of diagnosing iron-deficiency and anemia due to such causes as inflammation and hepatic or renal disease. In addition, serum ferritin concentration may be useful in detecting iron overload, which may allow the detection of idiopathic hemachromatosis in the precirrhotic storage.
    ID gène
    3164
    Pathways
    Transition Metal Ion Homeostasis
Vous êtes ici:
Support technique