Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

FOXD4 Kit ELISA

Kit ELISA Humain FOXD4, test Colorimetric pour la quantification de Humain FOXD4.
N° du produit ABIN6227711

Aperçu rapide pour FOXD4 Kit ELISA (ABIN6227711)

Antigène

Tous les produits FOXD4
FOXD4 (Forkhead Box D4 (FOXD4))

Reactivité

Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Gamme de detection

0.313 ng/mL - 20 ng/mL

Application

ELISA

Type d'échantillon

Cell Lysate, Tissue Homogenate
  • Seuil minimal de détection

    0.313 ng/mL

    Fonction

    Human Forkhead Box Protein D4 (FOXD4) ELISA Kit

    Analytical Method

    Quantitative

    Sensibilité

    < 0.188 ng/mL

    Ingrédients

    The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
    • Pre-coated 96-Well Microplate
    • Standard
    • Standard Diluent Buffer
    • Wash Buffer
    • Detection Reagent A
    • Detection Reagent B
    • Diluent A
    • Diluent B
    • TMB Substrate
    • Stop Solution
    • Plate Sealer

    Matériel non inclus

    • 37 °C incubator
    • Multi and single channel pipettes and sterile pipette tips
    • Squirt bottle or automated microplate washer
    • 1.5 mL tubes
    • Distilled water
    • Absorbent filter papers
    • 100 mL and 1 liter graduated cylinders
    • Microplate reader (wavelength: 450 nm)
    • ELISA Shaker
  • Indications d'application

    Optimal dilutions/concentrations should be determined by the end user.

    Commentaires

    The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.

    Plaque

    Pre-coated

    Préparation des réactifs

    This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.

    • 1) Standard: Prepare the standard with the recommended volume of Standard Diluent Buffer, to make the standard solution. Then use the Standard Diluent buffer to carry out serial dilutions of the standard solution, as instructed in the Protocol.
    • 2) Wash Buffer: Dilute the concentrated Wash Buffer with distilled water, as instructed in the Protocol.
    • 3) Detection Reagent Preparation: Calculate the total volume of working solution required. Dilute Detection Reagent A and Detection Reagent B with Diluent A and Diluent B, respectively, at 1:100.

    Prélèvement de l'échantillon

    • Serum: Samples should be collected into a serum separator tube. Coagulate the serum by leaving the tube undisturbed in a vertical position overnight at 4 °C or at room temperature for up to 60 minutes. Centrifuge at approximately 1000 x g for 20 min. Analyze the serum immediately or aliquot and store at -20 °C or -80 °C.
    • Plasma: Collect plasma using heparin or EDTA as an anticoagulant. Centrifuge for 15 minutes at 1000 x g within 30 minutes of collection. Assay immediately or aliquot and store at -20 °C or -80 °C. Avoid hemolysis and high cholesterol samples.
    • Tissue homogenates: The preparation of tissue homogenates will vary depending upon tissue type - this is just an example. Rinse tissues with ice-cold PBS to remove the excess of blood. Weigh before homogenization. Finely mince tissues and homogenize with a tissue homogenizer on ice in PBS and sonicate the cell suspension. Centrifuge the homogenates at 5000 x g for 5 min and collect the supernatant. Assay immediately or aliquot and store at -20 °C.

    Restrictions

    For Research Use only
  • Stock

    4 °C

    Stockage commentaire

    Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.

    Date de péremption

    6 months
  • Antigène Tous les produits FOXD4

    FOXD4 (Forkhead Box D4 (FOXD4))

    Autre désignation

    Forkhead Box Protein D4

    Sujet

    Ensembl: ENSG00000170122

    UniProt Entry Name: FOXD4_HUMAN

    ID gène

    2298

    HGNC

    3805

    OMIM

    601092

    UniProt

    Q12950