Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

CXCL13 Kit ELISA

CXCL13 Reactivité: Souris Colorimetric Sandwich ELISA 2-2000 pg/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN625114
  • Antigène Voir toutes CXCL13 Kits ELISA
    CXCL13 (Chemokine (C-X-C Motif) Ligand 13 (CXCL13))
    Reactivité
    • 7
    • 6
    • 3
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Souris
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    2-2000 pg/mL
    Seuil minimal de détection
    2 pg/mL
    Application
    ELISA
    Fonction
    Mouse BLC (CXCL13) ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Type d'échantillon
    Serum, Plasma, Cell Culture Supernatant
    Analytical Method
    Quantitative
    Specificité
    This ELISA kit shows no cross-reactivity with any of the cytokines tested: Mouse CD30, L CD30, T CD40, CRG-2, CTACK, CXCL16, Eotaxin , Eotaxin-2, Fas Ligand, Fractalkine, GCSF, GM-CFS, IFN- gamma, IGFBP-3, IGFBP-5, IGFBP-6, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-3 Rb, IL-4, IL-5, IL-9, IL-10, IL-12 p40/p70, IL-12 p70, IL-13, IL-17, KC, Leptin R, LEPTIN(OB), LIX, L-Selectin, Lymphotactin, MCP-1, MCP-5, M-CSF, MIG, MIP-1 alpha, MIP-1 gamma, MIP-2, MIP-3 beta, MIP-3 alpha, PF-4, P-Selectin, RANTES, SCF, SDF-1 alpha, TARC, TCA-3, TECK, TIMP-1, TNF-alpha, TNF RI, TNF RII, TPO, VCAM-1, VEGF.
    Sensibilité
    < 2 pg/mL
    Attributs du produit
    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data
    Ingrédients
    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate
    Matériel non inclus
    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
    Featured
    Discover our best selling CXCL13 Kit ELISA
    Top Product
    Discover our top product CXCL13 Kit ELISA
  • Indications d'application
    Recommended Dilution for serum and plasma samples20 - 100 fold
    Volume d'échantillon
    100 μL
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.
    Préparation des réactifs
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use.
      2. Sample dilution: If your samples need to be diluted, Assay Diluent A (Item D) should be used for dilution of serum/plasma samples. 1x Assay Diluent B (Item E) should be used for dilution of culture supernatants. Suggested dilution for normal serum/plasma: 20-100 fold. Please note that levels of the target protein may vary between different specimens. Optimal dilution factors for each sample must be determined by the investigator.
      3. Assay Diluent B should be diluted 5-fold with deionized or distilled water.
      4. Preparation of standard: Briefly spin the vial of Item C and then add 400 µL Assay Diluent A (for serum/plasma samples) or 1x Assay Diluent B (for cell culture medium) into Item C vial to prepare a 50 ng/mL standard. Dissolve the powder thoroughly by a gentle mix. Add 20 µL BLC standard from the vial of Item C, into a tube with 980 µL Assay Diluent A or 1x Assay Diluent B to prepare a 1,000 pg/mL stock standard solution. Pipette 400 µL Assay Diluent A or 1x Assay Diluent B into each tube. Use the stock standard solution to produce a dilution series . Mix each tube thoroughly before the next transfer. Assay Diluent A or 1x Assay Diluent B serves as the zero standard (0 pg/mL). 200 µL 200myl 200 µL 200 µL 200 µL 200 µL 20 µL standard + 980 µL 1000 333.3 111.1 37.04 12.35 4.11 1.37 0 pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL
      5. If the Wash Concentrate (20x) (Item B) contains visible crystals, warm to room temperature and mix gently until dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to yield 400 ml of 1x Wash Buffer.
      6. Briefly spin the Detection Antibody vial (Item F) before use. Add 100 µL of 1x Assay Diluent B into the vial to prepare a detection antibody concentrate. Pipette up and down to mix gently (the concentrate can be stored at 4 °C for 5 days). The detection antibody concentrate should be diluted 80-fold with 1x Assay Diluent B and used in step 4 of Part VI Assay Procedure.
      7. Briefly spin the HRP-Streptavidin concentrate vial (Item G) before use. HRP-Streptavidin concentrate should be diluted 200-fold with 1x Assay Diluent B. For example: Briefly spin the vial (Item G) and pipette up and down to mix gently . Add 70 µL of HRP-Streptavidin concentrate into a tube with 14 ml 1x Assay Diluent B to prepare a 200 fold diluted HRP- Streptavidin solution (don't store the diluted solution for next day use). Mix well.
    Procédure de l'essai
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate.
      2. Add 100 µL of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or over night at 4 °C with gentle shaking.
      3. Discard the solution and wash 4 times with 1x Wash Solution. Wash by filling each well with Wash Buffer (300 myl) using a multi-channel Pipette or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
      4. Add 100 µL of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking.
      5. Discard the solution. Repeat the wash as in step
      6. Add 100 µL of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking.
      7. Discard the solution. Repeat the wash as in step
      8. Add 100 µL of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking.
      9. Add 50 µL of Stop Solution (Item I) to each well. Read at 450 nm immediately.
    Calcul des résultats

    Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the average zero standard optical density. Plot the standard curve on log-log graph paper or using Sigma plot software, with standard concentration on the x-axis and absorbance on the y-axis. Draw the best-fit straight line through the standard points.
    Typical Data: These standard curves are for demonstration only. A standard curve must be run with each assay. Assay Diluent A Mouse BLC concentration (pg/mL) 0.1 1 10 100 1000 O D =4 50 n m 0.01 0.1 1 10 Assay Diluent B Mouse BLC concentration (pg/mL) 0.1 1 10 100 1000 O D =4 50 n m 0.01 0.1 1 10
    Sensitivity: The minimum detectable dose of BLC is typically less than 2 pg/mL.
    Recovery: Recovery was determined by spiking various levels of mouse BLC into mouse serum, plasma and cell culture media. Mean recoveries are as follows: Sample Type Average % Recovery Range ( %) Serum 96.89 83-103 Plasma 97.65 84-104 Cell culture media 104.56 90-110
    Linearity: Sample Type Serum Plasma Cell Culture Media 1:2 Average % of Expected 96 97 99 Range ( %) 85-104 86-105 87-106 1:4 Average % of Expected 98 95 103 Range ( %) 86-105 83-103 89-108
    Reproducibility: Intra-Assay: CV<10 % Inter-Assay: CV<12 %

    Précision du teste
    Intra-Assay: CV< 10 % Inter-Assay: CV< 12 %
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    Avoid repeated freeze-thaw cycles.
    Stock
    -20 °C
    Stockage commentaire
    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
    Date de péremption
    6 months
  • Antigène Voir toutes CXCL13 Kits ELISA
    CXCL13 (Chemokine (C-X-C Motif) Ligand 13 (CXCL13))
    Autre désignation
    BLC (CXCL13 Produits)
    Synonymes
    4631412M08Rik Kit ELISA, ANGIE2 Kit ELISA, Angie Kit ELISA, BCA-1 Kit ELISA, BLC Kit ELISA, BLR1L Kit ELISA, Scyb13 Kit ELISA, ANGIE Kit ELISA, BCA1 Kit ELISA, SCYB13 Kit ELISA, C-X-C motif chemokine ligand 13 Kit ELISA, chemokine (C-X-C motif) ligand 13 Kit ELISA, Cxcl13 Kit ELISA, CXCL13 Kit ELISA
    Sujet
    The Mouse BLC ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of mouse BLC in serum, plasma, cell culture supernatants and urine. This assay employs an antibody specific for mouse BLC coated on a 96-well plate. Standards and samples are pipetted into the wells and BLC present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-mouse BLC antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of BLC bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. Reproducibility: Intra-Assay: CV<10% Inter-Assay: CV<12%.