Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Ferritin Kit IQ-ELISA

FE Reactivité: Humain qPCR Sandwich ELISA Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN6384519
  • Antigène Voir toutes Ferritin (FE) IQ-ELISA Kits
    Ferritin (FE)
    Reactivité
    • 5
    • 4
    • 4
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    qPCR
    Type de méthode
    Sandwich ELISA
    Application
    ELISA
    Fonction
    Human Immunoquantitative (PCR-Based) Ferritin ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Type d'échantillon
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Semi-Quantitative
    Sensibilité
    60 pg/mL
    Attributs du produit
    IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    Ingrédients
    • Ferritin Microplate (Item A): 96 well PCR plate coated with anti-Human Ferritin
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Human Ferritin
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for Ferritin (Item F): 2 vials of a 4x concentrated solution of anti-Human Ferritin affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    Matériel non inclus
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Featured
    Discover our best selling FE Kit ELISA
    Top Product
    Discover our top product FE Kit ELISA
  • Indications d'application
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    Commentaires

    The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.

    Volume d'échantillon
    25 µL
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    Restrictions
    For Research Use only
  • Stock
    4 °C,-20 °C,-80 °C
    Stockage commentaire
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    Date de péremption
    6 months
  • Antigène Voir toutes Ferritin (FE) IQ-ELISA Kits
    Ferritin (FE)
    Autre désignation
    Ferritin (FE Produits)
    Synonymes
    1HCH Kit IQ-ELISA, BEST:LD36673 Kit IQ-ELISA, CG2216 Kit IQ-ELISA, Dmel\\CG2216 Kit IQ-ELISA, FER1 Kit IQ-ELISA, FER1HCH Kit IQ-ELISA, Fer-L Kit IQ-ELISA, Fer1 Kit IQ-ELISA, Fer1HC Kit IQ-ELISA, FerHCH Kit IQ-ELISA, HCH Kit IQ-ELISA, T21 Kit IQ-ELISA, T9 Kit IQ-ELISA, fer1 Kit IQ-ELISA, fer1hch Kit IQ-ELISA, l(3)00451 Kit IQ-ELISA, l(3)j10B4 Kit IQ-ELISA, SFerH-1 Kit IQ-ELISA, SOF-35 Kit IQ-ELISA, SOF-5L Kit IQ-ELISA, NV13011 Kit IQ-ELISA, ACP1 Kit IQ-ELISA, F8A5.24 Kit IQ-ELISA, F8A5_24 Kit IQ-ELISA, Ferritin 1 heavy chain homologue Kit IQ-ELISA, ferritin light chain Kit IQ-ELISA, ferritin Kit IQ-ELISA, chromosome 26 open reading frame, human C10orf131 Kit IQ-ELISA, hyaluronan and proteoglycan link protein 2 Kit IQ-ELISA, NAD(P)-linked oxidoreductase superfamily protein Kit IQ-ELISA, Fer1HCH Kit IQ-ELISA, H-1 Kit IQ-ELISA, YPDSF_1340 Kit IQ-ELISA, ftnA Kit IQ-ELISA, Ft Kit IQ-ELISA, C26H10orf131 Kit IQ-ELISA, HAPLN2 Kit IQ-ELISA, AT1G60730 Kit IQ-ELISA
    ID gène
    2495
    UniProt
    P02794
    Pathways
    Transition Metal Ion Homeostasis
Vous êtes ici:
Support technique