AAV9 Kit ELISA

AAV9 Reactivité: Adeno-Associated Virus 9 (AAV-9) Colorimetric Sandwich ELISA 10200000 capsids/mL - 650000000 capsids/mL Cell Culture Supernatant, Cell Lysate
N° du produit ABIN7448144
$1,183.23
Plus shipping costs $45.00
96 tests
Destination: Etats-Unis
Envoi sous 3 à 5 jours ouvrables
  • Antigène See all AAV9 products
    AAV9 (Adeno-Associated Virus 9 (AAV9))
    Reactivité
    Adeno-Associated Virus 9 (AAV-9)
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    10200000 capsids/mL - 650000000 capsids/mL
    Seuil minimal de détection
    10200000 capsids/mL
    Application
    ELISA
    Fonction
    This kit uses sandwich ELISA to determine the titer of AAV9 capsids in the test sample.
    Type d'échantillon
    Cell Culture Supernatant, Cell Lysate
    Analytical Method
    Quantitative
    Specificité
    Intact AAV wild type virions, AAV recombinant virions, Assembled AAV virions, Intact empty AAV capsids
    Sensibilité
    10000000 capsids/mL
    Ingrédients
    • Pre-coated 96-well plate
    • Reference Standard
    • Detection Antibody
    • HRP Conjugate
    • Assay Buffer (10 x concentrate)
    • Wash Buffer (20 x concentrate)
    • TMB Substrate
    • Stop Solution
    • Instruction manual
  • Indications d'application
    Empty AAV9 capsids lacking the transgene of interest cause unwanted immune response without providing the therapeutic benefit of the transgene. Alongside DNA and infectious titer, determination of the capsid titer is crucial for validating the efficacy and safety of your AAV gene therapy. Our titration kit detects full and empty AAV9 capsids. Note: User has the option of a rapid protocol (2 hours) for fast turnaround or a standard protocol (6 hours) for greater sensitivity.
    Volume d'échantillon
    100 µL
    Durée du test
    2 h
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards,
    2. Add 100μL standard or sample to each well. Incubate 1 hour at 37 °C,
    3. Aspirate and wash with 300 µL 1x Wash buffer 4 times,
    4. Add 100μL Detection Antibody. Incubate 1 hour at 37 °C,
    5. Aspirate and wash with 300 µL 1x Wash buffer 4 times,
    6. Add 100μL Streptavidin-HRP conjugate. Incubate 1 hour at 37 °C,
    7. Aspirate and wash with 300 µL 1x Wash buffer 4 times,
    8. Add 100 μL TMB Substrate. Incubate 10 minutes in the dark at 37 °C,
    9. Add 50μL Stop Solution. Read at 450nm immediately.
    Préparation des réactifs
    1. Prepare 1X Wash Buffer (Dilute 20X Wash Buffer with distilled H2O)
    2. Prepare 1X Assay Buffer (Dilute 10X Assay Buffer with distilled H2O)
    3. Prepare 1X Detection Antibody (Dilute the detection antibody (500X) with 1X Assay Buffer)
    4. Preparation of AAV9 capsid standards: Add 1mL of distilled H2O to one vial of standard. Dissolve at room temperature for 20 min. Centrifuge at 1000 rpm for 30 sec. The titer of the reconstituted standard is 6.50E+08 capsids/mL. Two-fold serial dilution of the AAV9 standard with 1X Assay Buffer for the titration curve in duplicates is recommended.
    5. Sample preparation: The supernatant of cell culture could be used directly or after dilution with cell lysis buffer (not provided). Cells should be treated with lysis buffer (not provided) and diluted with 1X assay buffer for sample preparation. Dilute the sample with 1X Assay Buffer to make the capsid titer quantification fall within the linear range.
      6.50E+08 capsids/mL, 3.25E+08 capsids/mL, 1.63E+08 capsids/mL, 8.13E+07 capsids/mL, 4.06E+07 capsids/mL, 2.03E+07 capsids/mL, 1.02E+07 capsids/mL.
    Préparation de l'échantillon
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
    Précision du teste
    CV < 5% indicates high accuracy. CV should be < 10% for each standard and sample. Retest any samples with CV > 10%.
    Restrictions
    For Research Use only
  • Stock
    4 °C/-20 °C
    Stockage commentaire
    Store the standard and detection antibody at -20 °C and the other kit components at 2-8 °C. The kit is valid for 6 months from the production date.
    Date de péremption
    6 months
  • Antigène See all AAV9 products
    AAV9 (Adeno-Associated Virus 9 (AAV9))
    Autre désignation
    AAV9 (AAV9 Produits)
Vous êtes ici: