IREM1 Kit ELISA
Aperçu rapide pour IREM1 Kit ELISA (ABIN8055546)
Antigène
Voir toutes IREM1 Kits ELISAÉpitope
Reactivité
Méthode de détection
Type de méthode
Gamme de detection
Application
Type d'échantillon
-
-
Seuil minimal de détection
- 31.2 pg/mL
-
Fonction
- Sandwich Human CD300F ELISA Kit to quantitate Human CD300LF in cell culture supernatants, serum and plasma (heparin, EDTA).
-
Analytical Method
- Quantitative
-
Specificité
-
Expression system for standard: E.coli
Immunogen sequence: T20-S156Capture antibody and Detection antibody: A monoclonal antibody from mouse|a biotinylated detection polyclonal antibody from goat
-
Réactivité croisée (Details)
- There is no detectable cross-reactivity with other relevant proteins.
-
Sensibilité
- < 10 pg/mL
-
Ingrédients
-
- Pre-coated 96-well strip microplate
- Standard
- Biotinylated antibody (100x)
- Avidin-Biotin-Peroxidase Complex (100x)
- Sample Diluent
- Antibody Diluent
- Avidin-Biotin-Peroxidase Diluent
- Color Developing Reagent (TMB)
- Stop Solution
- Wash Buffer (25x)
- Adhesive plate sealers
-
Matériel non inclus
- Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional). Pipettes and pipette tips capable of precisely dispensing 0.5 μL through 1 mL volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500 mL graduated cylinders. Test tubes for dilution.
-
-
-
-
Indications d'application
- Before using Kit, spin tubes and bring down all components to bottom of tube. Duplicate well assay was recommended for both standard and sample testing.
-
Volume d'échantillon
- 100 μL
-
Plaque
- Pre-coated
-
Protocole
- ELISA Kit is based on standard sandwich enzyme-linked immune-sorbent assay technology. An antibody has been precoated onto 96-well plates. Standards and test samples are added to the wells, a biotinylated detection antibody specific for target is added subsequently and then followed by washing with PBS or TBS buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with PBS or TBS buffer. HRP substrate TMB was used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the target amount in sample captured in plate.
-
Précision du teste
-
Intra-Assay Precision (CV%): 6.2%, 5.3%, 4.7%
Inter-Assay Precision (CV%): 6.1%, 7.4%, 5.1% -
Restrictions
- For Research Use only
-
-
-
Conseil sur la manipulation
- Avoid multiple freeze-thaw cycles.
-
Stock
- 4 °C,-20 °C
-
Stockage commentaire
- Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
-
Date de péremption
- 12 months
-
-
- IREM1 (Immune Receptor Expressed On Myeloid Cells 1 (IREM1))
-
Autre désignation
- CD300LF
-
Sujet
-
Background: CMRF35-like molecule 1 is a protein that in humans is encoded by the CD300LF gene. It is mapped to 17q25.1. This gene encodes a member of the CD300 protein family. Members of this family are cell surface glycoproteins with a single IgV-like extracellular domain, and are involved in the regulation of immune response. The encoded protein is an inhibitory receptor. Alternative splicing results in multiple transcript variants.
Gene Full Name: CD300 Molecule like family member f
-
ID gène
- 146722
-
UniProt
- Q8TDQ1
Antigène Voir toutes IREM1 Kits ELISA
-