Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

OAS3 Kit ELISA

Kit ELISA OAS3 Humain, Colorimetric test pour la quantification de Humain OAS3.
N° du produit ABIN8073793
840,00 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 12 à 18 jours ouvrables

Aperçu rapide pour OAS3 Kit ELISA (ABIN8073793)

Antigène

Voir toutes OAS3 Kits ELISA
OAS3 (2'-5' Oligoadenylate Synthetase 3 (OAS3))

Reactivité

  • 9
  • 2
  • 2
Humain

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Gamme de detection

0.156 ng/mL - 10 ng/mL

Application

ELISA

Type d'échantillon

Plasma, Serum, Tissue Homogenate
  • Seuil minimal de détection

    0.156 ng/mL

    Fonction

    Human 2',5'-Oligoadenylate Synthetase 3 (OAS3) ELISA Kit for detecting OAS3 in serum, plasma, tissue homogenates

    Analytical Method

    Quantitative

    Sensibilité

    0.062 ng/mL

    Ingrédients

    • Pre-coated, ready to use 96-well strip plate
    • Standar
    • Detection Reagent A
    • Detection Reagent B
    • TMB Substrate
    • Stop Solution
    • Assay Diluent A
    • Assay Diluent B
    • Wash Buffer (30x concentrate)
    • Standard Diluent
    • Plate Sealer
    • Instruction Manual

    Matériel non inclus

    • Microplate Reader with 450 nm filter
    • Single or multi-channel pipettes with high precision and disposable tips
    • Microcentrifuge tubes
    • Deionized or distilled watter
    • Absorbent paper for blotting the microplate
    • Container for wash solution
    • 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
  • Indications d'application

    Optimal working dilution should be determined by the investigator.

    Commentaires

    This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

    Volume d'échantillon

    100 μL

    Durée du test

    3 h

    Plaque

    Pre-coated

    Précision du teste

    Intra-Assay: CV<10%,
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Stock

    4 °C

    Stockage commentaire

    4°C for one month, Long term: see manual.

    Date de péremption

    12 months
  • Antigène Voir toutes OAS3 Kits ELISA

    OAS3 (2'-5' Oligoadenylate Synthetase 3 (OAS3))

    Autre désignation

    2',5'-Oligoadenylate Synthetase 3

    Sujet

    Gene Aliases: p100OAS

    ID gène

    4940

    UniProt

    Q9Y6K5

    Pathways

    Hepatitis C
Vous êtes ici:
Chat with us!