CKM Kit ELISA

Ce kit ELISA Colorimetric est conçu pour la mesure quantitative de Rat CKM.
N° du produit ABIN955838

Aperçu rapide pour CKM Kit ELISA (ABIN955838)

Antigène

Voir toutes CKM Kits ELISA
CKM (Creatine Kinase, Muscle (CKM))

Reactivité

  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
Rat

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Gamme de detection

7.8-500 U/L

Application

ELISA
  • Seuil minimal de détection

    7.8 U/L

    Fonction

    This ELISA kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of Rat CK-M in serum, plasma and other biological fluids.

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Rat CK-M. No significant cross- reactivity or interference was observed.

    Sensibilité

    The minimum detectable dose of Rat CK-M is typically less than 2.1 U/L. The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by the mean O.D. value of 20 replicates of the zero calibrator plus three standard deviations.

    Attributs du produit

    The microtiter plate provided in this kit has been pre-coated with an antibody specific to CK-M. Calibrators and samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for CK-M. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the TMB substrate solution is added to each well. Only those wells that contain CK-M, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 2 nm. The concentration of CK-M in the samples is then determined by comparing the O.D. of the samples to the calibration curve.

    Ingrédients

    Pre-coated, ready to use 96-well plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).

    Matériel non inclus

    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. Deionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution
  • Commentaires

    The calibration curve concentrations used for the ELISA's were 500, 250, 125, 62.5, 31.2, 15.6, 7.8 U/L.

    Plaque

    Pre-coated

    Calcul des résultats

    Average the duplicate readings for each calibrator, control, and sample and subtract the average zero calibrator optical density. Create a calibration curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a calibration curve by plotting the mean absorbance for each calibrator on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the CK-M concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. It is recommended to use some related software to do this calculation. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions

    For Research Use only
  • Stock

    -20 °C

    Stockage commentaire

    All reagents should be stored according to their label. The Calibrators, Detection Reagent A, Detection Reagent B and the 96-well plate should be stored at -20° C upon receipt. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date, provided they are stored as above.

    Date de péremption

    The expiry date is stated on the label.
  • Antigène Voir toutes CKM Kits ELISA

    CKM (Creatine Kinase, Muscle (CKM))

    Autre désignation

    CK-M