Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Galectin 9 Kit ELISA

LGALS9 Reactivité: Souris Colorimetric Sandwich ELISA 15.6-1000 pg/mL
N° du produit ABIN955871
  • Antigène Voir toutes Galectin 9 (LGALS9) Kits ELISA
    Galectin 9 (LGALS9) (Lectin, Galactoside-Binding, Soluble, 9 (LGALS9))
    Reactivité
    • 5
    • 3
    • 3
    • 3
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Souris
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    15.6-1000 pg/mL
    Seuil minimal de détection
    15.6 pg/mL
    Application
    ELISA
    Fonction
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of mouse GAL9 in serum, plasma and other biological fluids.
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of mouse GAL9. No significant cross- reactivity or interference between mouse GAL9 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between mouse GAL9 and all the other analogues, therefore, cross reaction may still exist.
    Sensibilité
    15.6 - 1000 pg/mL
    The minimum detectable dose of mouse GAL9 is typically less than 6.2 pg/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    Attributs du produit
    The microtiter plate provided in this kit has been pre-coated with an antibody specific to GAL9. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for GAL9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain GAL9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 10 nm. The concentration of GAL9 in the samples is then determined by comparing the O.D. of the samples to the calibration curve.
    Ingrédients
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Matériel non inclus
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling LGALS9 Kit ELISA
    Top Product
    Discover our top product LGALS9 Kit ELISA
  • Commentaires

    The calibration curve concentrations used for the ELISA's were 1000 pg/mL, 500 pg/mL, 250 pg/mL, 125 pg/mL, 62.5 pg/mL, 31.2 pg/mL, 15.6 pg/mL.

    Plaque
    Pre-coated
    Calcul des résultats

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve on log-log graph paper, with GAL9 concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Stock
    -20 °C
    Stockage commentaire
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Date de péremption
    The expiry date is stated on the label.
  • Antigène Voir toutes Galectin 9 (LGALS9) Kits ELISA
    Galectin 9 (LGALS9) (Lectin, Galactoside-Binding, Soluble, 9 (LGALS9))
    Autre désignation
    GAL9 (LGALS9 Produits)
    Synonymes
    huat Kit ELISA, lgals9a Kit ELISA, ecalectin Kit ELISA, galectin-9 Kit ELISA, Lgals9 Kit ELISA, wu:fd20c09 Kit ELISA, zgc:111833 Kit ELISA, LGALS9 Kit ELISA, AA407335 Kit ELISA, AI194909 Kit ELISA, AI265545 Kit ELISA, LGALS35 Kit ELISA, Lgals5 Kit ELISA, gal-9 Kit ELISA, HUAT Kit ELISA, LGALS9A Kit ELISA, UAT Kit ELISA, UATP.I Kit ELISA, galectin 9 L homeolog Kit ELISA, galectin 9 Kit ELISA, lectin, galactoside-binding, soluble, 9 (galectin 9)-like 3 Kit ELISA, lectin, galactose binding, soluble 9 Kit ELISA, lgals9.L Kit ELISA, lgals9 Kit ELISA, lgals9l3 Kit ELISA, LGALS9 Kit ELISA, Lgals9 Kit ELISA
Vous êtes ici:
Support technique