Ghrelin Kit ELISA

GHRL Reactivité: Humain Colorimetric Competition ELISA 123.5-10000 pg/mL
N° du produit ABIN955873
  • Antigène Voir toutes Ghrelin (GHRL) Kits ELISA
    Ghrelin (GHRL)
    Reactivité
    • 10
    • 8
    • 7
    • 4
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Competition ELISA
    Gamme de detection
    123.5-10000 pg/mL
    Seuil minimal de détection
    123.5 pg/mL
    Application
    ELISA
    Fonction
    The kit is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of human GHRL in serum, plasma, tissue homogenates, cell culture supernates and other biological fluids.
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of human GHRL. No significant cross-reactivity or interference between human GHRL and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between human GHRL and all the analogues, therefore, cross reaction may still exist.
    Sensibilité
    123.5 - 10000 pg/mL
    The minimum detectable dose of human GHRL is typically less than 45.3 pg/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    Attributs du produit
    This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific for human GHRL has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled human GHRL and unlabeled human GHRL (Calibrators or samples) with the pre-coated antibody specific for human GHRL. After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of GHRL in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of GHRL in the sample.
    Ingrédients
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Matériel non inclus
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling GHRL Kit ELISA
    Top Product
    Discover our top product GHRL Kit ELISA
  • Commentaires

    The calibration curve concentrations used for the ELISA's were 10, 000 pg/mL, 3, 333.3 pg/mL, 1111.1 pg/mL, 370.4 pg/mL, 123.5 pg/mL.

    Plaque
    Pre-coated
    Calcul des résultats

    This assay employs the competitive inhibition enzyme immunoassay technique, so there is an inverse correlation between GHRL concentration in the sample and the assay signal intensity. Average the duplicate readings for each calibrator, control, and samples. Create a calibration curve on log-log or semi-log graph paper, with GHRL concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Stock
    -20 °C
    Stockage commentaire
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Date de péremption
    The expiry date is stated on the label.
  • Antigène Voir toutes Ghrelin (GHRL) Kits ELISA
    Ghrelin (GHRL)
    Autre désignation
    Ghrelin (GHRL Produits)
    Synonymes
    2210006E23Rik Kit ELISA, Ghr Kit ELISA, MTLRP Kit ELISA, MTLRPAP Kit ELISA, m46 Kit ELISA, Gh1-1 Kit ELISA, GRHL Kit ELISA, MTLRP-AP Kit ELISA, GHR Kit ELISA, ghrelin Kit ELISA, ghrelin and obestatin prepropeptide Kit ELISA, ghrelin/obestatin prepropeptide Kit ELISA, Ghrl Kit ELISA, GHRL Kit ELISA, ghrl Kit ELISA
    Pathways
    Positive Regulation of Peptide Hormone Secretion, Hormone Transport, Peptide Hormone Metabolism, Negative Regulation of Hormone Secretion, Synaptic Membrane, Feeding Behaviour