Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

GNRH1 Kit ELISA

GNRH1 Reactivité: Rat Colorimetric Competition ELISA 12.35-1000 pg/mL
N° du produit ABIN955876
  • Antigène Voir toutes GNRH1 Kits ELISA
    GNRH1 (Gonadotropin-Releasing Hormone 1 (Luteinizing-Releasing Hormone) (GNRH1))
    Reactivité
    • 7
    • 6
    • 6
    • 5
    • 4
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    Rat
    Méthode de détection
    Colorimetric
    Type de méthode
    Competition ELISA
    Gamme de detection
    12.35-1000 pg/mL
    Seuil minimal de détection
    12.35 pg/mL
    Application
    ELISA
    Fonction
    The kit is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of rat GnRH in serum, plasma, tissue homogenates and other biological fluids.
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of rat GnRH. No significant cross- reactivity or interference between rat GnRH and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between rat GnRH and all the analogues, therefore, cross reaction may still exist.
    Sensibilité
    The minimum detectable dose of rat GnRH is typically less than 5.21 pg/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    Attributs du produit
    This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific for rat GnRH has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled rat GnRH and unlabeled rat GnRH (Calibrators or samples) with the pre- coated antibody specific for rat GnRH. After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of GnRH in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of GnRH in the sample.
    Ingrédients
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Matériel non inclus
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling GNRH1 Kit ELISA
    Top Product
    Discover our top product GNRH1 Kit ELISA
  • Commentaires

    The calibration curve concentrations used for the ELISA's were 1000 pg/mL, 333.33pg/mL, 111.11 pg/mL, 37.04 pg/mL, 12.35 pg/mL.

    Plaque
    Pre-coated
    Calcul des résultats

    This assay employs the competitive inhibition enzyme immunoassay technique, so there is an inverse correlation between GnRH concentration in the sample and the assay signal intensity. Average the duplicate readings for each calibrator, control, and samples. Create a calibration curve on log-log or semi-log graph paper, with the log of the GnRH concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Stock
    -20 °C
    Stockage commentaire
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Date de péremption
    The expiry date is stated on the label.
  • Antigène Voir toutes GNRH1 Kits ELISA
    GNRH1 (Gonadotropin-Releasing Hormone 1 (Luteinizing-Releasing Hormone) (GNRH1))
    Autre désignation
    GnRH (GNRH1 Produits)
    Synonymes
    GNRH Kit ELISA, GRH Kit ELISA, HH12 Kit ELISA, LHRH Kit ELISA, LNRH Kit ELISA, Gnrh Kit ELISA, Gnrh2 Kit ELISA, Lhrh1 Kit ELISA, Lnrh Kit ELISA, hpg Kit ELISA, Gnrha Kit ELISA, Lhrh Kit ELISA, Rgnrhg1 Kit ELISA, CGNRH-I Kit ELISA, GnRH-I Kit ELISA, GnRH Kit ELISA, gnrh Kit ELISA, gnrh1 Kit ELISA, grh Kit ELISA, lhrh Kit ELISA, lnrh Kit ELISA, mdGnRH Kit ELISA, mdgnrh Kit ELISA, mfGnRH Kit ELISA, gonadotropin releasing hormone 1 Kit ELISA, gonadotropin releasing hormone 1 L homeolog Kit ELISA, prepro-gonadotropin-releasing hormone Kit ELISA, GNRH1 Kit ELISA, Gnrh1 Kit ELISA, gnrh1.L Kit ELISA, gnrh1 Kit ELISA
    Pathways
    Hormone Activity
Vous êtes ici:
Support technique