Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Malondialdehyde Kit ELISA

MDA Reactivité: Rat Colorimetric Competition ELISA 24.69-2000 ng/mL
N° du produit ABIN955931
  • Antigène Voir toutes Malondialdehyde (MDA) Kits ELISA
    Malondialdehyde (MDA)
    Reactivité
    • 6
    • 5
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Rat
    Méthode de détection
    Colorimetric
    Type de méthode
    Competition ELISA
    Gamme de detection
    24.69-2000 ng/mL
    Seuil minimal de détection
    24.69 ng/mL
    Application
    ELISA
    Fonction
    The kit is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of rat MDA in serum, plasma and other biological fluids.
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of rat MDA. No significant cross- reactivity or interference between rat MDA and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between rat MDA and all the analogues, therefore, cross reaction may still exist.
    Sensibilité
    The minimum detectable dose of rat MDA is typically less than 10.55 ng/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    Attributs du produit
    This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific for rat MDA has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled rat MDA and unlabeled rat MDA (Calibrators or samples) with the pre-coated antibody specific for rat MDA. After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of MDA in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of MDA in the sample.
    Ingrédients
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Matériel non inclus
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling MDA Kit ELISA
    Top Product
    Discover our top product MDA Kit ELISA
  • Commentaires

    The calibration curve concentrations used for the ELISA's were 2, 000 ng/mL, 666.67 ng/mL, 222.22 ng/mL, 74.07 ng/mL, 24.69 ng/mL.

    Plaque
    Pre-coated
    Calcul des résultats

    This assay employs the competitive inhibition enzyme immunoassay technique, so there is an inverse correlation between MDA concentration in the sample and the assay signal intensity. Low levels of MDA result in a high O.D. value, while high concentration of MDA results in a low signal. Average the duplicate readings for each calibrator, control, and samples. Create a calibration curve on log-log graph paper, with MDA concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Stock
    -20 °C
    Stockage commentaire
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Date de péremption
    The expiry date is stated on the label.
  • Antigène Voir toutes Malondialdehyde (MDA) Kits ELISA
    Malondialdehyde (MDA)
    Autre désignation
    Malondialdehyde / MDA (MDA Produits)
    Classe de substances
    Chemical
Vous êtes ici:
Support technique