Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

MMP3 Kit ELISA

MMP3 Reactivité: Rat Colorimetric Sandwich ELISA 0.312-20 ng/mL
N° du produit ABIN955935
  • Antigène Voir toutes MMP3 Kits ELISA
    MMP3 (Matrix Metallopeptidase 3 (Stromelysin 1, Progelatinase) (MMP3))
    Reactivité
    • 9
    • 5
    • 4
    • 3
    • 3
    • 3
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Rat
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.312-20 ng/mL
    Seuil minimal de détection
    0.312 ng/mL
    Application
    ELISA
    Fonction
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of rat MMP3 in serum, plasma and other biological fluids.
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of rat MMP3. No significant cross- reactivity or interference between rat MMP3 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us - complete the cross-reactivity detection between rat MMP3 and all the analogues, therefore, cross reaction may still exist.
    Sensibilité
    The minimum detectable dose of rat MMP3 is typically less than 0.118 ng/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. value of 20 replicates of the zero calibrator plus three standard deviations.
    Attributs du produit
    The microtiter plate provided in this kit has been pre-coated with a monoclonal antibody specific to MMP3. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin- conjugated polyclonal antibody preparation specific for MMP3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain MMP3, biotin-conjugated antibody and enzyme- conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 10 nm. The concentration of MMP3 in the samples is then determined by comparing the O.D. of the samples to the calibration curve.
    Ingrédients
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    Matériel non inclus
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling MMP3 Kit ELISA
    Top Product
    Discover our top product MMP3 Kit ELISA
  • Commentaires

    The calibration curve concentrations used for the ELISA's were 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.312 ng/mL.

    Plaque
    Pre-coated
    Calcul des résultats

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve on log-log graph paper with MMP3 concentration on the y-axis and absorbance on the x-axis. Draw the best fit straight line through the calibrator points and it can be determined by regression analysis. Using some plot software is also recommended. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Stock
    -20 °C
    Stockage commentaire
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    Date de péremption
    The expiry date is stated on the label.
  • Antigène Voir toutes MMP3 Kits ELISA
    MMP3 (Matrix Metallopeptidase 3 (Stromelysin 1, Progelatinase) (MMP3))
    Autre désignation
    MMP3 (MMP3 Produits)
    Synonymes
    CHDS6 Kit ELISA, MMP-3 Kit ELISA, SL-1 Kit ELISA, STMY Kit ELISA, STMY1 Kit ELISA, STR1 Kit ELISA, SLN-1 Kit ELISA, SLN1 Kit ELISA, STR-1 Kit ELISA, Stmy1 Kit ELISA, Str1 Kit ELISA, MMP10 Kit ELISA, chds6 Kit ELISA, mmp-3 Kit ELISA, mmp13 Kit ELISA, mmp3 Kit ELISA, sl-1 Kit ELISA, stmy Kit ELISA, stmy1 Kit ELISA, str1 Kit ELISA, matrix metallopeptidase 3 Kit ELISA, matrix metallopeptidase 3 (stromelysin 1, progelatinase) Kit ELISA, matrix metallopeptidase 3 L homeolog Kit ELISA, MMP3 Kit ELISA, Mmp3 Kit ELISA, mmp3.L Kit ELISA
Vous êtes ici:
Support technique