CRP Kit ELISA

Kit ELISA CRP Singe, Colorimetric test pour la quantification de Singe CRP.
N° du produit ABIN956104
1.017,00 €
Plus frais de livraison 40,00 € et TVA
96 tests
Destination: France
Envoi sous 15 à 22 jours ouvrables

Aperçu rapide pour CRP Kit ELISA (ABIN956104)

Antigène

Voir toutes CRP Kits ELISA
CRP (C-Reactive Protein (CRP))

Reactivité

  • 30
  • 18
  • 18
  • 10
  • 8
  • 8
  • 7
  • 6
  • 4
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
Singe

Méthode de détection

Colorimetric

Type de méthode

Sandwich ELISA

Application

ELISA

Type d'échantillon

Serum
  • Fonction

    The Monkey High-Sensitive CRP ELISA is based on a solid phase enzyme-linked immunosorbent assay (ELISA).

    Analytical Method

    Quantitative

    Attributs du produit

    The Monkey High-Sensitive CRP ELISA is based on a solid phase enzyme-linked immunosorbent assay (ELISA). The assay uses affinity purified anti-monkey CRP antibodies for solid phase (microtiter wells) immobilization and horseradish peroxidase (HRP) conjugated anti-monkey CRP antibodies for detection. The test sample is diluted and incubated in the microtiter wells for 45 minutes. The microtiter wells are subsequently washed and HRP conjugate is added and incubated for 45 minutes. This results in CRP molecules being sandwiched between the immobilization and detection antibodies. The wells are then washed to remove unbound HRP-labeled antibodies and TMB Reagent is added and incubated for 20 minutes at room temperature. This results in the development of a blue color. Color development is stopped by the addition of Stop Solution, changing the color to yellow, and optical density is measured spectrophotometrically at 450 nm. The concentration of CRP is proportional to the optical density of the test sample.

    Ingrédients

    Anti-monkey CRP antibody coated microtiter plate with 96 wells (provided as 12 detachable strips of 8)
    Enzyme Conjugate Reagent, 11 mL
    Monkey CRP Calibrator, lyophilized
    Diluent (10X), 25 mL
    Wash Solution (20X), 50 mL
    TMB Reagent (One-Step), 11 mL
    Stop Solution (1N HCl), 11 mL.

    Matériel non inclus

    Precision pipettes and tips
    Distilled or de-ionized water
    Polypropylene tubes
    Vortex mixer
    Absorbent paper or paper towels
    Micro-Plate incubator/shaker mixing speed of ~150 rpm
    A microtiter plate reader with an capable of measuring absorbance at 450 nm
    Graph paper (PC graphing software is optional)
  • Plaque

    Pre-coated

    Protocole

    The assay uses affinity purified anti-monkey CRP antibodies for solid phase (microtiter wells) immobilization and horseradish peroxidase (HRP) conjugated anti-monkey CRP antibodies for detection. The test sample is diluted and incubated in the microtiter wells for 45 minutes. The microtiter wells are subsequently washed and HRP conjugate is added and incubated for 45 minutes. This results in CRP molecules being sandwiched between the immobilization and detection antibodies. The wells are then washed to remove unbound HRP-labeled antibodies and TMB Reagent is added and incubated for 20 minutes at room temperature. This results in the development of a blue color. Color development is stopped by the addition of Stop Solution, changing the color to yellow, and optical density is measured spectrophotometrically at 450 nm. The concentration of CRP is proportional to the optical density of the test sample.

    Préparation de l'échantillon

    General Note: We find that CRP is present in normal pooled monkey serum at a concentration of ~5 µg/mL and in-house studies indicate that acute phase concentrations can exceed 150 µg/mL. We suggest that samples initially be diluted 1,000 fold using the following procedure for each sample to be tested:
    1. Dispense 999 µL of 1X diluent into one tube for each sample to be tested.
    2. Pipette 1.0 µL of the serum sample into the tube containing 999 µL of 1X diluent using a precision micro pipettor and mix. This provides a 1,000 fold diluted sample.
    3. Repeat this procedure for each sample to be tested.

    Procédure de l'essai

    1. Secure the desired number of coated wells in the holder.
      2. Dispense 100 µL of calibrators and diluted samples into the wells (we recommend that samples be tested in duplicate).
      3. Incubate on an orbital micro-plate shaker at 150 rpm at room temperature (18-25°C) for 45 minutes.
      4. Remove the incubation mixture by flicking plate contents into an appropriate Bio-waste container.
      5. Wash and empty the microtiter wells 5 times with 1X wash solution. This may be performed using either a plate washer (400 µL/well) or with a squirt bottle. The entire wash procedure should be performed as quickly as possible.
      6. Strike the wells sharply onto adsorbent paper or paper towels to remove all residual wash solution.
      7. Add 100 µL of enzyme conjugate reagent into each well.
      8. Incubate on an orbital micro-plate shaker at 150 rpm at room temperature (18-25°C) for 45 minutes.
      9. Wash as detailed in 4 to 5 above.
      10. Strike the wells sharply onto absorbent paper or paper towels to remove residual wash solution.
      11. Dispense 100 µL of TMB Reagent into each well.
      12. Gently mix on an orbital micro-plate shaker at 150 rpm at room temperature (18-25°C) for 20 minutes.
      13. Stop the reaction by adding 100 µL of Stop Solution to each well.
      14. Gently mix. It is important to make sure that all the blue color changes to yellow.
      15. Read the optical density at 450 nm with a microtiter plate reader within 15 minutes.

    Calcul des résultats

    1. Calculate the average absorbance values (A450) for each set of reference calibrators, and samples.
      2. Construct a calibration curve by plotting the mean absorbance obtained from each reference calibrator against its concentration in ng/mL on linear graph paper, with absorbance values on the vertical or Y-axis and concentration on the horizontal or X-axis.
      3. Using the mean absorbance value for each sample, determine the corresponding concentration of CRP in ng/mL from the calibration curve.
      4. Multiply the derived concentration by the dilution factor to determine the actual concentration of CRP in the serum sample.
      5. If available, PC graphing software may be used for the above steps. We find that data usually fit well to a two site binding (hyperbola) equation.
      6. If the A450 values of samples fall outside, or at the extremes, of the calibration curve when tested at a dilution of 1,000, samples should be diluted appropriately and re-tested.

    Restrictions

    For Research Use only
  • Stock

    4 °C/-20 °C

    Stockage commentaire

    The lyophilized reference Calibrator should be stored at or below -20°C for optimum stability. The remainder of the kit should be stored at 4°C and the microtiter plate should be kept in a sealed bag with desiccant to minimize exposure to damp air. Test kits will remain stable until the expiration date provided that the components are stored as described above.

    Date de péremption

    The expiry date is stated on the label.