Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Total Antioxidant Capacity Kit ELISA

Ce kit ELISA Chemical est un kit ELISA Colorimetric conçu pour quantifier Chemical .
N° du produit ABIN956217

Aperçu rapide pour Total Antioxidant Capacity Kit ELISA (ABIN956217)

Antigène

Total Antioxidant Capacity

Reactivité

Chemical

Méthode de détection

Colorimetric

Type de méthode

Competition ELISA

Gamme de detection

21.9-4378 μmol/L

Application

ELISA
  • Seuil minimal de détection

    21.9 μmol/L

    Analytical Method

    Quantitative

    Sensibilité

    21.9 μmol/L

    Attributs du produit

    Oxidative stress plays an important role in various diseases and aging. The control of oxidative stress is expected to be useful to prevent diseases and aging. Oxidative stress is caused by the imbalance between reactive oxygen species (ROS) and antioxidant defense system. For accurate assessment of oxidative stress, measurement of ROS, oxidative damage and antioxidant activity may be essential. PAO can detect not only hydrophilic antioxidants such as Vitamin C and glutathione, but can also detect hydrophobic antioxidants such as Vitamin E. Applicable for the assessment of total antioxidants of serum, foods, and beverage samples. For research use only.Samples are mixed with Cu++ Solution. Cu++ are reduced by antioxidants to form Cu+. Reduced Cu+ react with Chromatic Solution (Bathocuproine), and can be detected by absorbance at wavelength 480 to 490 nm. Antioxidant capacity can be calculated from the Cu+ formed.

    Ingrédients

    1. Calibrator (Uric acid powder): 1 vial (for 2 mM), Dissolve with distilled water.
    2. Sample diluent: 60 mL x 1 bottle, Ready to use.
    3. Cu++ solution: 5 mL x 1 bottle, Ready to use.
    4. Stop solution: 5 mL x 1 bottle, Ready to use.
    5. Microtiter plate: 1 plate

    Matériel non inclus

    A. A microplate reader (measuring wavelength 490 nm)
    B. Pipettes and pipette chips
    C. Plastic test tubes
    D. Distilled water
    E. NaOH, HCl solution and pH meter (Not required if calibrators are prepared with distilled water only.).
  • Plaque

    Pre-coated

    Restrictions

    For Research Use only
  • Stock

    RT

    Stockage commentaire

    Store at room temperature until the expiration date listed on the kit box label.

    Date de péremption

    The expiry date is stated on the label.
  • Antigène

    Total Antioxidant Capacity

    Autre désignation

    Total Antioxidant Capacity (PAO)
Vous êtes ici:
Chat with us!