TIMP3 Kit ELISA
Aperçu rapide pour TIMP3 Kit ELISA (ABIN1112684)
Antigène
Voir toutes TIMP3 Kits ELISAReactivité
Méthode de détection
Type de méthode
Gamme de detection
Application
Type d'échantillon
-
-
Seuil minimal de détection
- 156 pg/mL
-
Fonction
- For quantitative detection of TIMP-3 in Human serum, plasma, tissue lysatesor cell culture supernatants.
-
Analytical Method
- Quantitative
-
Sensibilité
- < 2 pg/mL
-
Ingrédients
- 1. One 96-well plate pre-coated with anti-Human TIMP-3 antibody 2. Lyophilized Human TIMP-3 standards: 2 tubes (10ng / tube) 3. Sample / Standard diluent buffer: 30ml 4. Biotin conjugated anti-Human TIMP-3 antibody (Concentrated): 130 µl.
-
Matériel non inclus
-
- 37 °C incubator
- Microplate reader (wavelength: 450 nm)
- Precise pipette and disposable pipette tips
- Automated plate washer
- ELISA shaker
- 1.5 mL of Eppendorf tubes
- Plate cover
- Absorbent filter papers
- Plastic or glass container with volume of above 1 L
-
-
-
-
Indications d'application
- Optimal working dilution should be determined by the investigator.
-
Commentaires
-
This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Anti-TIMP-3 polyclonal antibody was pre-coated onto 96-well plates. And the biotin conjugated anti-TIMP-3 polyclonal antibody was used as detection antibodies. The standards test samples and biotin conjugated detection antibody were added - the wells subsequently and wash with wash buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with wash buffer. TMB substrates were used - visualize HRP enzymatic reaction. TMB was catalyzed by HRP - produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional - the TIMP-3 amount of sample captured in plate. Read the O.D. absorbance at 450 nm in a microplate reader and then the concentration of TIMP-3 can be calculated.
-
Plaque
- Pre-coated
-
Préparation des réactifs
-
- Before the experiment, centrifuge each kit component for several minutes to bring down all reagents to the bottom of tubes. 2. It is recommend to measure each standard and sample in duplicate. 3. Do NOT let the plate completely dry at any time! Since the dry condition can inactivate the biological material on the plate. 4. Do not reuse pipette tips and tubes to avoid cross contamination. 5. Do not use the expired components and the components from different batches. 6. To avoid the marginal effect of plate incubation for temperature differences (the marginal wells always get stronger reaction), it is recommend to equilibrate the ABC working solution and TMB substrate for at least 30 min at room temperature (37 °C ) before adding to wells.The TMB substrate (Kit Component 8) is colorless and transparent before use, if not, please contact us for replacement.
-
Préparation de l'échantillon
-
Preparation of sample and reagents 1. Sample Isolate the test samples soon after collecting, then, analyze immediately (within 2 hours). Or aliquot and store at -20 °C for long term. Avoid multiple freeze-thaw cycles.
Tissue lysate, body fluids and cell culture supernatants: Centrifuge to remove precipitate, analyze immediately or aliquot and store at -20 °C .
Serum: Coagulate the serum at room temperature (about 4 hours). Centrifuge at approximately 1000 × g for 15 min. Analyze the serum immediately or aliquot and store at -20 °C .
Plasma: Collect plasma with heparin or EDTA as the anticoagulant. Centrifuge for 15 min at 1000 x g within 30 min of collection. Analyze immediately or aliquot and store frozen at -20 °C. Citrate can not be used as anticoagulant here. Note: 1. Coagulate blood samples completely, then, centrifuge, and avoid hemolysis and particle. 2. NaN3 can not be used as test sample preservative, since it is the inhibitor for HRP. -
Restrictions
- For Research Use only
-
-
-
Agent conservateur
- Sodium azide, Thimerosal (Merthiolate)
-
Stock
- 4 °C,-20 °C
-
Stockage commentaire
- Store at 2-8°C for 6 months, or at -20°C for 12 months.
-
Date de péremption
- 12 months
-
-
- TIMP3 (TIMP Metallopeptidase Inhibitor 3 (TIMP3))
-
Autre désignation
- TIMP-3
-
Sujet
- Metalloproteinase inhibitor 3 is an protein that in humans is encoded by the TIMP3 gene, which maps to to chromosome 22. This gene belongs to the tissue inhibitor of metalloproteinases gene family. The proteins encoded by this gene family are inhibitors of the matrix metalloproteinases, a group of peptidases involved in degradation of the extracellular matrix (ECM). Expression of this gene is induced in response to mitogenic stimulation and this netrin domain-containing protein is localized to the ECM. The balance of MMP and TIMP determines the net migratory capacity of DCs. Mutations in this gene have been associated with the autosomal dominant disorder Sorsby's fundus dystrophy.