TIE1 Kit ELISA

TIE1 Reactivité: Humain Colorimetric Sandwich ELISA 312.50-20000 pg/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN3198483
  • Antigène Voir toutes TIE1 Kits ELISA
    TIE1 (tyrosine Kinase with Immunoglobulin-Like and EGF-Like Domains 1 (TIE1))
    Reactivité
    • 3
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    312.50-20000 pg/mL
    Seuil minimal de détection
    312.50 pg/mL
    Application
    ELISA
    Fonction
    This assay employs the quantitative sandwich enzyme immunoassay technique for quantitative detection.
    Type d'échantillon
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Quantitative
    Specificité
    Tie1, Human
    Sensibilité
    107.84 pg/mL
    Ingrédients
    Plate, Standard, Diluent
    Matériel non inclus
    Microplate reader capable of measuring absorbance at 450 nm, with correction wavelength set at 570 nm or 630 nm.
    Pipettes and pipette tips.
    50 μL to 300 μL adjustable multichannel micropipette with disposable tips.
    Multichannel micropipette reservoir.
    Beakers, flasks, cylinders necessary for preparation of reagents.
    Deionized or distilled water.
    Polypropylene test tubes for dilution.
    Featured
    Discover our best selling TIE1 Kit ELISA
    Top Product
    Discover our top product TIE1 Kit ELISA
  • Volume d'échantillon
    100 μL
    Durée du test
    3 - 4 h
    Plaque
    Pre-coated
    Restrictions
    For Research Use only
  • Buffer
    Buffer contains: 0.02 % sodium azide
    Agent conservateur
    Sodium azide
    Précaution d'utilisation
    This product contains Sodium azide: a POISONOUS AND HAZARDOUS SUBSTANCE which should be handled by trained staff only.
    Conseil sur la manipulation
    Intended for research use only and are not for use in diagnostic or therapeutic procedures.
    Treat all chemicals with caution because they can be potentially hazardous.
    It is recommended that this product is handled only by persons who have been trained in laboratory techniques and in accordance with the principles of good laboratory practice. Wear personal protection equipment such as laboratory coat, safety glasses and gloves.
    Avoid direct contact with skin or eyes. Wash immediately with water in the case of contact with skin or eyes. Avoid contact of skin or mucous membranes with kit reagents or specimens. See material safety data sheet(s) for specific advice.
    Pure water or deionized water must be used for reagent preparation.
    The Stop Solution provided with this kit is an acid solution. Wear personal protection equipment with caution.
    Do not expose kit reagents to strong light during storage and incubation.
    Rubber or disposable latex gloves should be worn while handling kit reagents or specimens.
    Avoid contact of substrate solution with oxidizing agents and metal.
    Avoid splashing or generation of aerosols.
    Use disposable pipette tips and/or pipettes to avoid microbial or cross-contamination of reagents or specimens which may invalidate the test.
    Use clean, dedicated reagent trays for dispensing the conjugate and substrate reagent.
    Exposure to acid inactivates the HRP and antibody conjugate.
    Substrate solution must be warmed to room temperature prior to use.
    Decontaminate and dispose specimens and all potentially contaminated materials as they could contain infectious agents. The preferred method of decontamination is autoclaving for a minimum of 1 hour at 121.5 °C.
    Liquid wastes not containing acid and neutralized waste may be mixed with sodium hypochlorite in volumes such that the final mixture contains 1.0 % sodium hypochlorite. Allow 30 minutes for effective decontamination. Liquid waste containing acid must be neutralized prior to the addition of sodium hypochlorite.
    All reagents including microplate, samples, standards and working solution should be warmed to room temperature before use.
    To obtain accurate results, using adhesive film to seal the plate during incubation is suggested.
    It is recommended that all samples and standards be assayed in duplicate.
    Avoid foaming when mixing or reconstituting solutions containing protein.
    To avoid cross-contamination, use separate reservoirs for each reagent and change pipette tips between each standard, sample and reagent.
    When using an automated plate washer, adding a 30 seconds soak period before washing step and/or rotating the plate between wash steps may improve assay precision.
    When pipetting reagents, maintain a consistent order of addition from well-to-well.
    Keep Substrate solution protected from direct strong light. Substrate Solution should turn to gradations of blue after a proper color development.
    Read absorbance within 30 minutes after adding stop solution.
    Take care not to scratch the inner surface of the microwells.
    Stock
    4 °C
    Stockage commentaire
    Store kit reagents between 2 and 8 °C. Immediately after use remaining reagents should be returned to cold storage (2 to 8 °C).
    Expiry of the kit and reagents is stated on labels. Expiration date of the kit components can only be guaranteed if the components are stored properly, and if, in case of repeated use of one component, this reagent is not contaminated by the first handling.
    Unopened Kit: Store at 2 - 8 °C (See expiration date on the label).
    Opened/Reconstituted Reagents: Up to 1 month at 2 - 8 °C.
    Reconstituted Standard: Up to 1 month at ≤ -20 °C in a manual defrost freezer. Avoid repeated freeze-thaw cycles.
    Microplate Wells: Up to 1 month at 2 - 8 °C. Return unused strips to the foil pouch containing the desiccant pack, reseal along entire edge to maintain plate integrity. Provided this is within the expiration date of the kit
  • Antigène Voir toutes TIE1 Kits ELISA
    TIE1 (tyrosine Kinase with Immunoglobulin-Like and EGF-Like Domains 1 (TIE1))
    Autre désignation
    Tie1 (TIE1 Produits)
    Synonymes
    JTK14 Kit ELISA, TIE Kit ELISA, D430008P04Rik Kit ELISA, tie-1 Kit ELISA, tyrosine kinase with immunoglobulin like and EGF like domains 1 Kit ELISA, tyrosine kinase with immunoglobulin-like and EGF-like domains 1 Kit ELISA, tyrosine-protein kinase receptor Tie-1 Kit ELISA, endothelium-specific receptor tyrosine kinase 1 Kit ELISA, TIE1 Kit ELISA, Tie1 Kit ELISA, CpipJ_CPIJ018933 Kit ELISA, tie1 Kit ELISA
    Sujet
    Tyrosine-protein kinase receptor Tie1, is a single-pass type I membrane protein which belongs to the protein kinase superfamily, Tyr protein kinase family and Tie subfamily.
    ID gène
    7075
    NCBI Accession
    NM_001253357, NM_005424
    UniProt
    P35590
    Pathways
    Signalisation RTK
Vous êtes ici:
Support technique